3.13 Speed regulation

Reducing the rotation speed
x1
+
Press „Stop" and „Down"
button simultaneously for
2 seconds

3.14 Resetting to factory default

x3
Press P1 for
12 seconds

4. Maintenance

Generally the motor requires no maintenance. However, it should be noted, that other parts installed within the whole system may be subject to wear
and tear. Therefore, the whole system should be regularly checked for signs of wear and tear or other such issues.

5. Technical Data

Item no.
Motor head reception
Motor length without bracket
Motor diameter
Nominal voltage
Power
Rated torque
Max. load
Rated rpm
Rated current
Battery, fixed inside
Max. charging voltage
Battery capacity
Protection class
Protection type VDE 700
Charging port
Compatible charger
Radio frequency
Radio code
Sound pressure
We reserve the right to change the product specifications and design for performance enhancement purposes.

6. Test run

Please start a test run of the venetian blind into both directions, ensuring that the motor stops at the previously set limits.
Increasing the rotation speed
x1
+
Press „Stop" and „Up"
button simultaneously
for 2 seconds
ERJSSDC06-34
[mm]
Single shaft
[mm]
130
[mm]
24
[V] DC
12
[W]
8
[Nm]
0,6
[kg]
4
[rpm]
34
[A]
0,63
Li-Io
[V] DC
12.6
[mAh]
550
III
IP20
Power jack plug socket
HR1200LA-12.6
433,92
[MHz]
G2
< 70
[db(A)]
Note! - This function is not available when using the
controls HD05B, HD15BT, HR120033WA, HR120038G2,
HR1200-SUN-G2 and HR1300-WIND-G2!