The transmission between appropriate central stations and the
GSM module is constantly monitored by sending presence
(heartbeat) messages to central station receivers.
Advisor Master
Advisor Master control panels do not support GPRS and OH
receiver communication. For this purpose, ATS1809 must be
installed. Refer to ATS1809 Universal Interface Installation and
Programming Guide for the information on required
programming settings.
Advisor Advanced
To program the required polling time in Advisor Advanced, go
to menu "Heartbeat time" and set a value from every second
(00:00'01) to every day (23:59'59).
In case of the dual path reporting, if the primary CS
communication fails, the backup CS heartbeat time is switched
from normal to frequent according to a value configured in the
menu "Frequent HB time".
For programming details, see Advisor Advanced Installation
and Programming Manual. The required settings for each ATS
category are listed in Chapter "Regulations", section
"Transmitter polling interval requirements".
Substitution and information security
Triple-DES, Symmetric encryption algorithms are used
with key length 192 bits.
In case hash functions are used, they give a minimum of
128 bits output.
Regular automatic key changes are used with machine
generated randomized keys.

Specifications

Power supply:
Via ribbon cable from control panel 10 to 15 V
Current consumption (at 13.8 V
MI bus (idle)
MI bus (GSM online)
MI bus (GSM max.)
Wireless operating frequency:
GSM 850
E-GSM 900
DCS 1800
PCS 1900
Maximum power output:
GSM 850, E-GSM 900
DCS 1800, PCS 1900
Dimensions
Battery type and max. capacity
Weight
Temperature
Relative humidity
Serviceable parts
SPT type
P/N 466-2906-ML • REV C • ISS 18SEP18
±5%):
20 mA
40 mA
340 mA
824 to 849 MHz
880 to 915 MHz
1710 to 1785 MHz
1850 to 1910 MHz
2 W
1 W
104 x 50 mm
See the appropriate control
panel installation manual
44 g
−10 to +50°C
Max 95% noncondensing
There are no serviceable
parts in ATS7320
EN 50131-10: 2014 Type Y
[1]
[1]
ATS7320 (Type Y) only meets the EN 50131-10:2014
requirements when it is installed in a EN 50131-3:2009 or
EN 50131-6:2008 compliant housing.

Regulatory information

Manufacturer
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
Certification with ATS Master panel range.
This product was tested and certified to
EN 50136-2:2013 for Alarm transmission system
performance SP2 for reporting over PSTN.
Tested and certified by Telefication B.V.
Certification with ATS Advanced series.
This product was tested and certified to
EN 50136-2:2013 for Alarm transmission system
performance SP3 for reporting over GPRS to the
OH Receiver.
This product was tested and certified to
EN 50136-2:2013 for Alarm transmission system
performance SP4 for reporting over GPRS to the
OH Receiver.
This product was tested and certified to
EN 50136-2:2013 for Alarm transmission system
performance DP2 for backup reporting over
GPRS to the OH Receiver.
This product was tested and certified to
EN 50136-2:2013 for Alarm transmission system
performance DP3 for backup reporting over
GPRS to the OH Receiver.
Tested and certified by Telefication B.V.
Alarm transmission class: Pass-through operation
mode.
Environmental Class II.
In combination with an ATS Advisor Advanced
panel the ATS7320 dialler can be used in
installations up to and including EN 50131
Grade 2.
In combination with an ATS Advisor Advanced
Grade 3 panel the ATS7320 dialler can be used in
installations up to and including EN 50131
Grade 3.
In combination with an ATS Advisor Master panel
the ATS7320 dialler can be used in installations
up to and including EN 50131 Grade 3.
or scan the QR code.
5 / 44