Instruction manual BES M30MF2-PSC10B-BV02-EXD

Technical data

EU Examination of Conformity
IECEx Certificate
Ignition protection type (ATEX): Gas-Ex
Ignition protection type (IECEx): Gas-Ex
Temperature range in T6 (Zone 0)
Temperature range in T5 (Zone 0)
Temperature range in T4 (Zone 0)
Temperature range in T3 (Zone 0)
Temperature range in T6 (Zone 1)
Temperature range in T5 (Zone 1)
Temperature range in T4 (Zone 1)
Temperature range in T3 (Zone 1)
Temperature range dust-Ex (Zone 20)
Maximum surface temperature (Zone 20)
Temperature range dust-Ex (Zone 21)
Maximum surface temperature (Zone 21)
Rated Voltage
Supply voltage
Rated current
Switching current
Short-circuit current of external circuit
Electrostatic chargeable plastic housing
With reference to group II (gas):
With reference to group III (dust):
Housing material
Switching output
Switching distance Sn
Operating point
Hysteresis
Switching frequency
Test voltage
Degree of protection [EN 60529]
Electrical connection
Accessories
Trouble shooting
Failure
The functioning indicator does not light
up when the proximity switch is actuated
No change of
switching signal
Scope of delivery, transportation and disposal
• Inspect packaging and content for damage.
• Check the delivery for completeness.
• Disposal note: Do not dispose the device in the domestic waste, comply with relevant laws and national regulations.
BA-S36037-GB-2018-20
Dust-Ex
Dust-Ex
Cause of failure
Supply voltage too low or
not connected
Operation of the proximity
switch outside of specification
EPS 18 ATEX 1 015 X
IECEx EPS 18.0011X
II 1G Ex ma IIC T6 Ga
II 1D Ex ma IIIC T90°C Da
Ex ma IIC T6 Ga
Ex ma IIIC T90°C Da
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
–20 °C ≤ Ta ≤ +60 °C
90 °C
–20 °C ≤ Ta ≤ +60 °C
90 °C
27 V DC
24 V DC ±10%
50 mA DC
50 mA DC
≤100 A
616 mm²
981 mm²
Br-Ni / PA
PNP-Normally open
10 mm flush
0.8 Sn
<0.1 Sn
300 Hz
500 V / 50 Hz / 60 s
IP 67
2 m PUR-cable, grey, 3x0.34 mm²
2x nut M30x1.5, Br-Ni
Remedy
Check power supply
Check range of application
of the proximity switch