Putting in the batteries
Putting in the batteries
1
Lower the battery access cover (5),
1
Lower the battery access cover (5),
2
Insert two LR03 1.5V batteries as shown in
2
Insert two LR03 1.5V batteries as shown in
the diagram drawn in the bottom of the
the diagram drawn in the bottom of the
product, ensuring correct polarity,
product, ensuring correct polarity,
3
Close the battery access cover (5).
3
Close the battery access cover (5).
Functional description
Functional description
G Temperature setting
G Temperature setting
Use dial (1) to set the desired comfort
Use dial (1) to set the desired comfort
temperature.
temperature.
Note:
Note:
Each time the appliance is switched
Each time the appliance is switched
ON or OFF the operating signal light (3)
ON or OFF the operating signal light (3)
lights
lights
ON:
1 flash
ON:
1 flash
OFF:
2 flashes
OFF:
2 flashes
Coding the transmitter with
Coding the transmitter with
the receiver
the receiver
1.
Press the press button (1) of the
1.
Press the press button (1) of the
receiver for more than 3 seconds.
receiver for more than 3 seconds.
- The product moves into
- The product moves into
"Configuration" mode , the signal light
"Configuration" mode , the signal light
"OK" (2) flashes slowly.
"OK" (2) flashes slowly.
2.
Press the MEMO button of the trans-
2.
Press the MEMO button of the trans-
mitter for at least three seconds.
mitter for at least three seconds.
- The signal light « OK » (2) stops
- The signal light « OK » (2) stops
flashing, showing that he transmis-
flashing, showing that he transmis-
sion/reception link has been
sion/reception link has been
established.
established.
- The receiver returns to the auto
- The receiver returns to the auto
mode.
mode.
Deleting the coding
Deleting the coding
1.
Press the push-button (1) for more than
1.
Press the push-button (1) for more than
10 seconds
10 seconds
- The signal light « OK » (2) flashes
- The signal light « OK » (2) flashes
slowly, then more quickly.
slowly, then more quickly.
2.
Press the push-button (1) of the
2.
Press the push-button (1) of the
receiver again, for more than
receiver again, for more than
3 seconds.
3 seconds.
- The signal light « OK » (2) stops flashing, all codes have been
- The signal light « OK » (2) stops flashing, all codes have been
cleared.
cleared.
4
+
+
+
- Supply: 2 alkaline batteries type LR03, 1.5 V not supplied
Supply
+
- Supply: 2 alkaline batteries type LR03, 1.5 V not supplied
(Lifetime about 1 year).
(Lifetime about 1 year).
Temperature setting range
- Temperature setting range: from +5°C to +30°C
5
- Temperature setting range: from +5°C to +30°C
5
Transmission frequency
- Transmission frequency: 433.92 MHz
- Transmission frequency: 433.92 MHz
Static differential
- Static differential: <0.5 K
Regulation mode
- Static differential: <0.5 K
- Regulation mode: PID
Transmission distance
- Regulation mode: PID
Dimensions
- Transmission distance: 100 m in clear field
- Transmission distance: 100 m in clear field
Operating temperature
- Dimensions: 120 x 80 x 35
Storage temperature
20
- Dimensions: 120 x 80 x 35
25
20
25
- Operating temperature: 0°C to 40C
15
Ecodesign class
1
- Operating temperature: 0°C to 40C
30
15
1
- Storage temperature: -20C to +6°C
Relative humidity
30
3
10
- Storage temperature: -20C to +6°C
C°
3
IP
10
5
C°
- Relative humidity: 90% max at 25°C
5
- Relative humidity: 90% max at 25°C
IK
+
- Insulation class: III
Emission power
+
- Insulation class: III
- IP: 31
Transmitter duty cycle
- IP: 31
Pollution category
- IK: 03
- IK: 03
Class software
Action type
Voltage and current declared for the needs of EMC emis-
sions tests:
Independent panel-mounted control device or for built-in
installation
Usable in all Europe
Hager Controls hereby declares that the Wireless room thermostat with radio
20
transmission device complies with the essential requirements and other
25
20
25
relevant provisions of Directive 2014/53/EU.
15
The CE declaration is available on the www.hagergroup.com site.
30
15
www.hagergroup.com
30
10
C°
10
5
C°
5
+
+
+
+
This marking shown on the waste or its literature indicates that it should not be dis-
posed with other household wasted at the end of its working life. To prevent pos-
sible harm to the environment or human health from uncontrolled waste disposal,
please separate this product from other types of wastes and recycle it responsibly
to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this pro-
duct, or their local government office, for details of where and how they can take
this device for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions
of the purchase contract. This product should not be mixed with other commercial
wastes of disposal.
Declaration of conformity:
Declaration of conformity:
We, Flash SAS, 33 rue Saint-Nicolas 67704 Saverne Cedex, declare
We, Flash SAS, 33 rue Saint-Nicolas 67704 Saverne Cedex, declare
on our own sole responsibility that the products of the present instruc-
on our own sole responsibility that the products of the present instruc-
tion sheet satisfy all the essential requirements linked with the direc-
tion sheet satisfy all the essential requirements linked with the direc-
tive R&TTA 1999/5/EC of March 1999.
tive R&TTA 1999/5/EC of March 1999.
Technical characteristics
Technical characteristics
2 alkaline batteries type LR03, 1.5 V not supplied
å
and in Switzerland
Correct Disposal of this product (Waste Electrical & Electronic Equip-
ment).
(Applicable in the European Union and other European countries with
separate collection systems).
Usable everywhere in Europe
Usable everywhere in Europe
The SA Controle Quality Manager / 04.03
The SA Controle Quality Manager / 04.03
(Lifetime about 1 year).
from +5°C to +30°C
433.92 MHz
<0.5 K
PID
100 m in clear field
120 x 80 x 35
0°C to 40°C
- 20C to +6°C
IV
90% max at 25°C
31
03
10mW
10%
2
Classe A
2
3V- 0A
6LE004101A