Herunterladen Inhalt Inhalt Diese Seite drucken

Qlima PGF 1211 Gebrauchsanweisung Seite 70

Vorschau ausblenden Andere Handbücher für PGF 1211:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
e)
ES
Apagado
Posición
de encen-
dido
Lo
Capacidad
baja
Hi
Alta capa-
cidad
Table 1
TO TURN OFF THE HEATER
a)
b)
WARNINGS
REPLACING THE GAS CYLINDER
4
70
position, fully close propane gas valve, wait 5 minutes, then repeat steps b–c.
Now, using a lighter, ignite the pilot light through the ignition hole on the
emitter screen. Once the pilot light is lit, depress control knob for 60 seconds.
After depressing the control knob for 60 seconds, turn control knob to LOW.
To increase the temperature, turn towards HIGH.
If the burner flame goes out accidentally or it is blown out by wind, turn off
the heater and wait at Ieast 5 minutes or more to let the gas dissipate before
re-lighting to avoid possible gas explosion. Repeat steps c to d.
FR
GB
Off
Off
Position
Ignite posi-
d'allumage
tion
Capacité
Low capac-
faible
ity
Capacité
High
élevée
capacity
Fully close gas valve.
Turn control knob clockwise to OFF position.
The whole gas system. hose, regulator, pilot and burner should be inspected
for Ieak before use. But at least once a month and each time the gas cylinder
is changed. Check the hose assembly for sign of extreme abrasion, cuts or
wears. Suspected areas should be Ieak tested. If the hose Ieaks, it must be
replaced with a new one that conforms to IocaI standard codes. ). If it shows
signs of cracking, splitting or other deterioration it shall be exchanged for
new hose of the same length and of the equivalent quality.
Make sure the ventilation opening of the cylinder enclosure, controI com-
partment, burner and circulation air passageways of the heater are free and
clear of debris. If debris, spider or insect nests are found, clean the holes with
heavyduty pipe cleaner or compressed air.
Always keep a dry chemical fire extinguisher readily available.
For safety, always allow a 5-minute complete shut off period before re-light-
ing a hot heater.
Replace the gas tube/hose within the interval described with the hose.
Shut off heater.
Close the valve of the gas cylinder.
Disconnect the regulator from the cylinder following the instructions that
came with your regulator.
Replace the cylinder.
Make sure there is no flame. Only when no flame: remove the plug or seal
cap from the cylinder valve.
Check for the presence and good state of the gasket before connecting the
IT
NL
PT
Spenta
Uit
Off
(Desligado)
Posizione
Ontstekings
Posição
di accen-
positie
para acen-
sione
der
Bassa capa-
Laag ver-
Baixa capa-
cità
mogen
cidade
Alta capa-
Hoog ver-
Elevada
cità
mogen
capacidade
SLO
Off
Vžgite
položaj
Nizka
kapaciteta
Velika
kapaciteta

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis