ACCESS CODE
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor.
If you forget the access code, cut and restore the power supply. During 1 minute, you can access the sensor without
introducing any access code.

TROUBLESHOOTING

The door remains
closed.
The LED is OFF.
The door does not
react as expected.
The door opens
and closes
constantly.
The door opens for
no apparent reason.
The LED
fl ashes quickly
after unlocking.
The sensor does
not respond to the
remote control.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.it - www.came.it
Came S.p.A. hereby declares that MR8106 is in conformity with the basic requirements and the other relevant provisions
of the directives R&TTE 1999/5/EC, LVD 2006/95/EC, RoHS 2 2011/65/EU.
For EC countries: according to the directive 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE).
Original upon request.
-
BUY
TO
The sensor power is off.
The door control setting (F2)
is set to value 3 (closed).
Improper output
confi guration on the sensor.
The sensor is disturbed
by the door motion or
vibrations caused by the
door motion.
It rains and the sensor
detects the motion of the
rain drops.
In highly refl ective
environments, the sensor
detects objects outside of its
detection fi eld.
In airlock vestibules,
the sensor detects the
movement of
the opposite door.
The sensor needs an access
code to unlock.
Batteries in the remote
control are weak or
installed improperly.
Remote control badly
pointed.
-
SELL PRODUCT
Check the wiring and the power supply.
1
Change the door control setting (F2) to value 1
1
(automatic).
Change the output confi guration setting on
1
each sensor connected to the door operator.
1
Make sure the sensor is fi xed properly.
Make sure the detection mode is unidirectional.
2
Increase the antenna angle.
3
4
Increase the immunity fi lter.
5
Reduce the fi eld size.
1
Make sure the detection mode is unidirectional.
2
Increase the immunity fi lter.
Install the ORA (rain accessory).
3
Change the antenna angle.
1
Decrease the fi eld size.
2
Increase the immunity fi lter.
3
Change the antenna angle.
1
Change the antenna.
2
Increase the immunity fi lter.
3
Enter the right access code.
1
If you forgot the code, cut and restore the power
2
supply to access the sensor without access code.
Change or delete the access code.
Check and change the batteries if necessary.
1
Point the remote control towards the sensor.
1

Werbung