Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice
versa, when mixer is closed
Spout temperature does not corre-
spond with temperature set
Temperature regulation not pos-
sible
Safety stop button not operating
On/off control stiff
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leak-
ing
- Thermostat has not been ad-
justed
- Hot water temperature too low
- Temperature regulator dirty or
calcified
- Spring defective
- Button calcified
- Cartridge on/off control defec-
tive, calcifiedt
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filters
- Clean filter seal between shower
and hose
- Clean backflow preventers, ex-
change if necessary
- Adjust thermostat
- Increase hot water temperature
to 42 °C to 65 °C
- Clean temperature regulator, ex-
change if necessary
- Clean spring and/or button, ex-
change if necessary
- Exchange cartridge on/off con-
trol
7