Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx Linking - Chauvet Professional OVATION F-55WW Kurzanleitung

Vorschau ausblenden Andere Handbücher für OVATION F-55WW:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
Replacing The Fuse
1.
Disconnect this product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.

DMX Linking

The Ovation F-55WW will work with a DMX controller using a 5-pin DMX serial connection. A DMX Primer is available
from
www.chauvetprofessional.com.
DMX Connection
The Ovation F-55WW uses a 5-pin DMX for its DMX personalities: 1, 2, or 5. See the User Manual for information about
connecting and configuring the product for DMX operation.
Master/Slave Connection
The Ovation F-55WW uses the DMX data connection for its Master/Slave mode. See the User Manual for information
about how to connect and configure the product for master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller's User Manual or with the manufacturer as not all DMX controllers
have this capability. The Ovation F-55WW supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from
Mounting
Before mounting this product, read the
mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps/
Product Mounting Diagram
Mounting Clamp
Ovation F-55WW QRG Rev. 2
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
www.chauvetprofessional.com
Safety
Notes. Use at least one mounting point per product. Make sure the
Overhead Mounting
Wire (Europe)
Brown
Blue
Green/Yellow
for more details.
EN
Screw Color
Yellow/Brass
Silver
Green
Safety Cable