Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal; Technical Data; Order List - Dräger VarioGard 2300 Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
7

Disposal

This product must not be disposed of as municipal waste.
This is indicated by the adjacent symbol. You can return this
product to Dräger free of charge. For information please
contact the national marketing organisations and Dräger.
8

Technical data

Environmental conditions
Operation
Storage
CE mark
Type of protection, housing
Transmitter
Weight
Plastic housing
Dimensions with
cable inlet (L x B x H):
Plastic housing
Cable inlet
Operating voltage
Power consumption
Dräger VarioGard 2300 / 2320
–30 to +40 °C
10 to 90 % rel. humidity
700 to 1300 hPa
0 to 30 °C for transmitters
10 to 95 % rel. humidity
700 to 1300 hPa
Electromagnetic compatibility
(Directive 2004/108/EC)
Low voltages
(Directive 2006/95/EC)
IP 65, EN 60529
approx. 0.4 kg
120 mm x 110 mm x 60 mm
M20 x 1.5; 6 mm to 12 mm
16 to 30 V DC
below 0.75 W
Measurement specifications:
Measuring
range
IR Ex sensor
0...100 %LEL
IR CO
sensor
0...5 % by vol. 100 ppm
2
9

Order list

Designation and description
VarioGard 2300 Ex
Measuring range 0 to 100 % LEL CH
VarioGard 2320 CO
2
Measuring range 0 to 5 vol.-% or 0 to 10000 ppm CO
Accessories
Cable inlet M 20 x 1.5 (pack of 10)
Calibration adaptor (VarioGard 23x0)
SW set VarioGard 23x0 (incl. USB PC adapter)
Magnetic wand
Disposal
Resolution
Measuring error
of display
1 %LEL
< ± 5 % of measured value
< ± 5 % of measured value
Order no.
83 24 832
or LPG
4
83 24 833
2
83 15 420
83 22 015
83 22 016
45 44 101
17

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Variogard 2320

Inhaltsverzeichnis