Herunterladen Inhalt Inhalt Diese Seite drucken

Preliminary Information - Giona ECOSYN 190-300 Installations-, Bedienungs- Und Wartungsanleitung

Luft-wasser-wärmepumpe für die erzeugung von brauchwarmwasser
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3 - GENERAL
UNIT INDENTIFICATION
Serial number label
The serial number label is positioned on the unit and allows to
indentify all the unit features.
It has not to be removed for any reason.
It reports the regulations indications such as:

unit type,

serial number (12 characters )

year of manufacture

wiring diagram number

electrical data

manufacturer logo and address .
Serial number
It identifies uniquely each machine.
It identifies specific spare parts for the machine.
Assistance request
Note data from the serial number label and write them in the
chart on side, so you will find them easily when needed.
In case of intervention you have to provide data.
Serie
Size
Serial number
Year of manufacture
Wiring diagram

PRELIMINARY INFORMATION

Before beginning the work, ensure you that have the final
project for installing the aeraulic, hydraulic, electric,drains and
positioning the units.
Operate in compliance with safety regulations in force .
Use single protection devices.
Recommended instruments
Set of Philips and flathead screwdrivers;
Cutters;
Drill;
Scissors;
Set of open spanners or pipe wrenches;
Range;
Hydraulic material for the sealing of the threads;
Electrical equipment for the connections;
Cut prevention gloves;
Tester and amperometric pliers.
BEFORE REQUESTING START-UP

Completed aeraulic system and free of dirt

Completed water system, circuit loading and venting

Discharges unit connected

Electric connections