Herunterladen Inhalt Inhalt Diese Seite drucken

Condensate Discharge - Giona ECOSYN 190-300 Installations-, Bedienungs- Und Wartungsanleitung

Luft-wasser-wärmepumpe für die erzeugung von brauchwarmwasser
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

11 - MAINTENANCE
11.14 REPLACE OR CONTROL THE ELECTRIC
HEATER
If the replace or control of the electric heater

Remove power supply

Remove frontal cover (A)

Unscrew the screws and remove the cover cap (B)

Turn off the water inlet valve (C)

Open hot water tap for decrease the pressure of the
storage tank.

Open tap (D)

Empty the storage up to point (E)

Disconnect the cable from the electric heater

Remove and replace the electric heater (If faulty)

Install the electrical resistance and make sure effective
sealed.

Check that there are no water losses from the fitting

Restore the electric connections

Put the cover cap (B) and fix

Put de frontal cover (A)

Open the water inlet tap (C) untill water flows out from
outlet tap, then turn of water outlet tap.

Power on then restart the unit.
E
C
D

11.15 CONDENSATE DISCHARGE

Dust and deposits could cause obstructions .
In addition in the pan can proliferate microorganisms and
moulds.
It is very important to provide a periodic cleaning with
appropriate detergents and in case a disinfection with
sanitizing products.
After cleaning pour water into the pan to ensure a regular flow.
A
B
Electric heater
Drain pan
52