12 - TECHNICAL DATA
Size
Ventilation
Type of fan
Air flow
Available pressure head
Integration
Solar coil surface
Solar coil material
Maximum operating pressure
1. Inlet water temperature 15 °C, accumulator set 45°C, air on source side 15°C D.B /12°C W.B.
2. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Average Climate, Heat Pump Water Heater
3. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Warmer Climate, Heat Pump Water Heater
4. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Colder Climate, Heat Pump Water Heater
5. Data referred to completely ducted unit.
6. Maximum temperature that can be reached during Anti-legionella mode(Dinsifect)
*It contains fluorinated greenhouse gases

ELECTRICAL DATA

1,50 kW Electric heating element
Size
Power supply
F.L.A. - Current absorbed at the maximum allowed conditions
F.L.I. - Power absorbed at full load (at the maximum allowed condi-
tions)
M.I.C - Maximum inrush current
3,00 kW Electric heating element
Size
Power supply
F.L.A. - Current absorbed at the maximum allowed conditions
F.L.I. - Power absorbed at full load (at the maximum allowed condi-
tions)
M.I.C - Maximum inrush current
1) Power supply 220-240/1/50 Hz
For power voltages other than the standard, contact the technical department
The units are conforming with the prescriptions of European Standards CEI EN 60204 and CEI EN 60335
Warning: when defining the correct size, verify that all absorption is compliant with current electrical supply
contracts in force in the country of installation
190
3
m
/h
270
Pa
25
2
m
-
-
bar
-
MPa
-
190
(1)
220-240/1/50
220-240/1/50
V
A
9,10
kW
2,10
A
22,2
190
(1)
220-240/1/50
220-240/1/50
V
A
16,1
kW
3,70
A
28,7
300
190 W
Centrifugal
414
270
25
25
-
1,10
-
Enamel Steel
-
10
-
1
300
190 W
220-240/1/50
220-240/1/50
9,80
9,10
2,25
2,10
33,7
22,2
300
190 W
220-240/1/50
220-240/1/50
16,5
16,1
3,75
3,70
40,2
28,7
300 W
414
25
1,30
10
1
300 W
9,80
2,25
33,7
300 W
16,5
3,75
40,2
56