5.3 Maintenance and Storage

• If the machine is deactivated for maintenance, inspec-
tion, storage, or for exchanging a part, (power unit
must be disconnected from the mains), ensure that
all moving parts are still and any tools/spanners have
been removed. Let the machine cool before any in-
spection or repair.
• When maintaining the blade mechanism, make sure
that the the power source cannot activate due to the
protective locking device; the blades could always be
activated by a hand-start mechanism.
5.4 Additional Safety Instructions for Devices with
Collecting Containers
• Shut down the shredder before attaching or removing
the collecting container.
6. Operating Instructions
WARNING: You may need help unpacking and
assembling the machine.
After unpacking and inspecting the shredder for damage,
proceed with the following steps:

6.1 Assembling the Garden Shredder

1
• Turn the shredder over.
• Fold both legs up and insert the supplied axle through
the openings.
• Place both washers on the left and ride side of the
axle.
2
• Place the supplied threaded spacer on the axle. Then
wheel covers.
WARNING: Be careful when leaning the device
on the wheels, since the weight is unbalanced
when titled and moved.
GB | Operating Instructions

6.2 Collecting Container

• Pull up the safety grip and slide the collecting contain-
7. Operation

7.1 On/off switch

4
• Press the on/off switch to switch on or off the shred-

7.2 Overload protection

Overload (e.g. blocking up of the chopping knife) will lead
to a standstill of the machine after a few seconds. To pro-
tect the motor from getting damaged, the overload switch
will automatically cut off the mains supply.
GB-5
er into the under frame.
3
der.
Note: This machine is equipped with an elec-
tromagnetic switch to prevent it from being
unexpectedly switched on when power source
recovered.
5
ing the reset button and then the on/off switch. If the
motor does not start, proceed as follows:
on/off
switch
Reset
button
-