a
MI/1753 - 4
ed. ENG - 11/2019
installation and maintenance sheet
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or transformed
and it must be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee. The company
cannot be held responsible for damage caused by incorrect assembly. PRECAUTIONS FOR ASSEMBLY - IMPORTANT! As it is a drive-over ground-recessed appliance, great care must be
taken in installation, scrupulously following the assembly instructions specified here. The appliance is tested for the penetration of water. The appliance should be positioned and installed
when closed, with the bulb already mounted and correctly adjusted in order to avoid dirt entering and compromising its watertightness.
Ø170
NO
well tamped sand and
gravel backfill
prefabricated pit
30x30x30cm
approx.
connection
accessory ACS/CR1
support bricks
fixed with a trowel
of mortar
frame
7 mm
upper casing
level flushing
to roadside
BEAM ADJUSTMENT
Model D44/T1-LW4 can reduce the number of beams and rotate them on the vertical axis.
Remove the fixture from the outer casing and take it to the edge of ground (
)
T
replace it if deformed. Make sure that the gasket is dead-centred in its housing. For a correct operation it
it is essential a frequent cleaning of the glass and of the outer surface of the fixture to avoid build up of
mud and dirtiness resulting in dangerous overheating due to uncorrect light and heath dissipation.
r
Quality control: In case of complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial
number that recognizes the fixture. / Specifications are subject to change without notice!
Ø 148
YES
fixture outer
casing
electric cables
sand and gravel
draining foundation,
hosed until refusal,
well set and tamped
30 cm
custodia esterna
apparecchio
connection
accessory ACS/CR1
electric cables
concrete block
lean concrete
draining layer
).
)
)
r.
D44-tellux/R1 D44K-tellux/R1
Features and meaning of the symbols shown on the label:
lighting appliance for indoor and outdoor ground-recessed installation.
Capable of withstanding the load of motor vehicles with inflatable tyres pumped
with air, maximum weight static or dynamic: 2000Kg.
Fixtures that can be utilized in all accessible areas, according to EN60598-2-13
version Class I
LW...
Do not install in areas where snowplows are used.
Version in Class I
: earth required
Version in Class II
: earth not required
totally dust-proof and watertight against powerful water jets
IP66 - IP67
will operate if occasionally submerged
heavy duty:
can withstand impacts up to 6,5 Nm
mounting on normally
inflammable surfaces allowed
replace the protection screen if damaged
with a plane float tempered glass – thickness 10 mm,
shock resistant 6,5Nm according to EN60598-1
getting rid of as urban waste forbidden
separate collection is mandatory when
the product is at the end of its life
EMBEDDED INSTALLA
for correct assembl
1) avoid positioning the fixture in areas of subsidence (
accumulate.
Picture 2
2)
50 cm deep.
3)
4)
5)
prefabricated pit.
6)
cables for the electrical connection of the fixture.
EMBEDDED INSTALLA
P
proceed as in the above points 1-2-3-4.
5) refer to
6)
cement per cubic metre of mixture. The block must have a diameter (or side) of not less than 30 cm.
ELECTRICAL CONNECTION
the electrical connection must be carr
Therefore, additional protection should be inserted into the electrical plant
1
product in compliance with the requirements
of the European Community Directories
75°C
20kN static load resistance.
version Class II
max. glas Temp. ta 25°C
LW...
40° C
P
f
r.
electrician.
f
ACS/CR1 or an equivalent
.
in the case of
.
2