DESCRIPTION AND INTENDED USE

ECO-LOGIC can only be installed on gate automation systems with V2 control units.
ATTENTION: the control unit supplied by the ECO-LOGIC must have the mode of operation ENERGY SAVING active.
To ensure proper operation of the system, all the added accessories must be connected to the accessory output of the control
unit and, during the stand-by, they will not be supplied.
The system consists of an accumulator unit, a solar panel and en external power supply.
The automation device is powered by the accumulator unit, which is recharged during daylight hours.
The external power supply (accessory - code 172802) may be used for recharging the batteries in the case of prolonged periods of lack of
sunlight.
NOTE: If the panel fails to provide sufficient charge to the accumulator group, it is possible to install a second panel in parallel to the
first one.
CAUTION: Before you connect the two panels, disconnect the grey connector from the accumulator
Exclusively use the panel with code 172801 provided by V2
To connect the two panels in parallel, use a 2x1mm
If the cable between the accumulator and the first panel is longer than 3m, use a 2x1, 5mm
ATTENTION: the connections must be insulated inside a waterproof container

TECHNICAL INFORMATION

Accumulator unit
Voltage output toward the control unit
Maximum current
Battery capacity
Protection level
Operating temperature
Mains recharge time
Dimensions
Weight
* NOTE: when no load is connected or drains are very low,
the accumulator output voltage can reach the value of the
voltage generated by the solar panel.
2
cable
24-28Vdc*
16A
18Ah
IP44
0 ÷ +40°C charging
-20 ÷ +50°C in use
~ 15 h
267x188,2x198 mm
12 Kg
8
2
cable
Solar panel
Maximum voltage without load
Voltage at maximum power point 33,6Vdc
Peak nominal power
Operating temperature
Dimensions
Weight
Mains power supply
Power supply
Max. nominal power
Operating temperature
Dimensions
Weight
42Vdc
20W
-20 ÷ +80°C
308x28x604 mm
2,2 Kg
230Vac - 50Hz
36W
0 ÷ +30°C
99x78x153 mm
1,7 Kg