Herunterladen Inhalt Inhalt Diese Seite drucken

IDEC HR1S-AF 5130B Bedienungsanleitung Seite 15

Safety relay module
Inhaltsverzeichnis

Werbung

HR1S-AF 5130B / PB SAFETY RELAY MODULE OPERATING INSTRUCTIONS
HR1S-AF 5130B / PB SAFETY RELAY MODULE OPERATING INSTRUCTIONS
- Fixation du boîtier:
Encliquetage sur profilé chapeau 35 mm selon
EN/IEC 60715
- Degré de protection selon EN/IEC 60529:
Bornes:
IP20
Boîtier:
IP40
- Poids:
0,25 kg
- Position de montage:
indifférente
- Température de fonctionnement:
-25°C / +55°C
- Catégorie de surtension III (4 kV)
Degré de pollution 2
Tension assignée d'isolement 300V
EN/IEC 60664-1
- Tension d'alimentation U
selon IEC 60038:
E
24V
(+10% / -15%)
(voir plaque signalétique)
Protection max.:
4 A gL
- Puissance consommée:
≤ 5 VA
Version 24V
- Sorties de sécurité (libre de potentiel):
13 - 14, 23 - 24, 33-34
- Capacité de coupure maxi des sorties:
AC-15: Ue = 240V
/ le = 0.75A
DC-13: Ue = 24V
/ le =1.5A
- Durée de vie mécanique (Commutations):
6
10 * 10
- Limite des courants cumulés (charge
simultanée des plusieurs circuits de sortie):
Σ Ith ≤ 18 A
6 A
- Protection des sorties:
max.: 4 A gL ou 6A rapide
- Temps de réponse,
≤ 20ms
S11-S12, S21-S22:
A1 ou A2:
≤ 60ms
- Temps de synchronisation entre entrée A et
entrée B à l'utilisation sans bouton de
démarrage:
t = ∞
L'appareil est aussi capable de commuter des
charges faibles (17V
/ 10 mA minimum), à
condition que le contact n'ait jamais commuté de
forte charge auparavant, car la couche d'or
revêtant le contact pourrait être altérée.
- Résistivité dans l'alimentation des
actionneurs:
max. 90 Ω
15 / 16
Multiple-wire connection (2 wires max.)
Without cable end:
solid
stranded
Stripping length:
Flexible with cable end (without plastic sleeve):
Flexible with TWIN-cable end (with plastic
sleeve):
Tightening torque, min.:
1)
AWG indication according to
selon
EN/IEC 60947-1 / table 1
- Mounting:
Mounting on 35 mm DIN rail according to
EN/IEC 60715
- Degree of protection according to EN/IEC
60529:
Terminals:
Enclosure:
- Weight:
- Mounting position: Any plane
- Ambient operating temperature:
-25°C to +55°C (-13°F to +130°F)
- Overvoltage category III (4 kV)
Pollution degree 2
Rated insulation voltage: 300V
according to EN/IEC 60664-1
- Supply voltage U
24V
(Refer to device nameplate for supply voltage)
Max. protection:
6 A
6 A
- Power consumption:
Version 24V
- Safety outputs:
13 - 14, 23 - 24, 33-34
- Maximum switching capacity of outputs:
AC-15: Ue = 240V
DC-13: Ue = 24V
- Mechanical service life (Switching operations):
6
10 * 10
- The sum of simultaneous currents on all of the
outputs is limited to :
Σ Ith ≤ 18 A.
- Protections of outputs:
max.: 4 A fuse (gL) or 6A fastblow
- Response time,
S11-S12, S21-S22:
A1 or A2:
- Synchronisation time between Input A and
Input B without use of start button (automatic
start):
Minimum switching ratings of outputs:
The device is capable to switch the low voltage
loads (min. 17V
contact has never been used with higher loads.
- Resistance in the voltage supply to the
sensors:
2
1)
0.2-1 mm
(24-18 AWG
)
2
1)
0.2-1.5 mm
(24-16 AWG
)
7 mm (0.28 in.)
2
1)
0.25-1 mm
(22-18 AWG
)
2
1)
0.5-1.5 mm
(20-16 AWG
)
0.5 Nm (4.4 lb-in)
IP20
IP40
0.25 kg (8.8 oz)
according to IEC 60038:
E
(+10% / -15%)
4 A fuse (gL)
≤ 5 VA
/ le = 0.75A
/ le =1.5A
6 A
6 A
6 A
≤ 20ms
≤ 60ms
t = ∞
/ 10 mA) provided that the
max. 90 Ω
- Gehäusebefestigung:
Schnappbefestigung auf 35 mm
Normschiene nach EN/IEC 60715
- Schutzart gemäß EN/IEC 60529:
Klemmen:
IP20
Gehäuse:
IP40
- Gewicht:
0,25 kg
- Einbaulage:
beliebig
- Umgebungstemperatur im Betrieb:
-25°C / +55°C
- Überspannungskategorie III (4 kV)
Verschmutzungsgrad 2
Bemessungsisolationsspannung 300V
gemäß EN/IEC 60664-1
- Anschlußspannung U
gemäß IEC 60038:
E
24V
(+10% / -15%)
(Siehe Typenschild)
Absicherung max.:
4 A gL
- Eigenverbrauch:
≤ 5 VA
Version 24V
- Sicherheitsausgänge (potentialfrei):
13 - 14, 23 - 24, 33-34
- Max. Schaltleistung der Ausgangskanäle:
AC-15: Ue = 240V
/ le = 0.75A
DC-13: Ue = 24V
/ le =1.5A
- Mechanische Lebensdauer (Schaltungen):
6
10 *10
- Summenstrombegrenzung bei gleichzeitiger
Belastung mehrerer Ausgangskreise:
Σ Ith ≤ 18 A.
6 A
- Absicherung der Ausgangskreise:
max.: 4 A gL oder 6A Flink
- Ansprechzeit,
≤ 20ms
S11-S12, S21-S22:
A1 oder A2:
≤ 60ms
- Synchronisationszeit zwischen Input A und
Input B bei Verwendung ohne Starttaster:
t = ∞
Das Gerät ist ebenfalls zum Schalten von
Kleinstlasten (min. 17V
/ 10 mA) geeignet.
Dies ist jedoch nur dann möglich, wenn bisher
über diesen Kontakt keine höheren Lasten
geschaltet wurden, da hierdurch die
Kontaktvergoldung abgebrannt sein könnte.
- Leitungswiderstand in der Spannungs-
versorgung der Befehlsgeber: max. 90 Ω
6 A
6 A

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hr1s-af 5130pb

Inhaltsverzeichnis