Installing ATAG One zone and activating the ATAG zone services is quick and easy:
it takes just 3 steps!
ATAG One zone
INSTALLATION
The term "Telediagnosis" (TD) means the Technical Assistance Centre service, which can pro-
vide remote support functions. The term "Telecontrol" (TC) means the end user service con-
trolling, monitoring and configuring the ATAG appliance with a smartphone app or web portal.
4. ATAG One zone INSTALLATION
The device detects the room temperature, therefore several factors should be taken into ac-
count when choosing an installation site. Position the device far from heat sources (radiators,
sunlight, fireplaces, etc.) and from draughts, doorways and windows which could affect the
temperature readings. It should be installed approximately 1.5 metres above the floor level.
WARNING!
Installation should be performed by a qualified technician.
Before making any connections, shut off electrical power to
the boiler with its external two-position switch.
- Secure the ATAG One zone base plate (A) to the wall and
connect the pair of wires to the terminal clamp to hook the
boiler up via the BUS.
- Fit the battery in its compartment (B).
- Reattach the ATAG One zone to its base plate (C) by pushing
it carefully downwards.
14 / EN