Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba RH-251218EEU Bedienungsanleitung Seite 15

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
B: If the scheduling time is set, press the standby key "
cancel the scheduling.
C: After the scheduling is started, press the scheduling key "
time of the appointment and reset the scheduling time. During the scheduled time, the
machine is shut down or started up under temperature control, and the scheduled time
is always normal, and free from down time. During the scheduled time, it is cleared in-
case of power failure,
<Child Lock Function>: In the working and the standby no child lock effective state,
press "
" and "MODE" for 3 seconds to turn on the child lock function. Under the
working status and the effective state of the standby open child lock, press "
"MODE" simultaneously for 3 seconds to turn off the child lock function.
Remarks: 1. when the working state running child lock take seffect, standby operation
can be performed. Other operations are invalid (except releasing the child lock); the
child lock is canceled after standby.
2. When the child lock is in effect during standby, all operations are invalid (except releas-
ing the child lock).
<Memory function>: After the machine is on standby, it will be started up again and will
operate according to the status before the last standby. Power off and power on again.
It is running in accordance with the state before the power failure .After normal stand-
by, and then power off, it will run at factory defaults, namely high-grade operation, set
the temperature to 35°C by default when powering on again.
Note: After power failure, the child lock function does no tremember.
<Safety protection function>:When the indoor ambient temperature Th exceeds 50°C
under the standby or working state, all out puts are turned off, the buzzer prompts 10
long as there is protection, even if the ambient temperature is less than 50°C, the run-
ning or operation can not be resumed, and the operation can only be performed after
the power is turned off and on again.
<Shut down>: Under the working state, press the standby key "
el to enter the standby state, unplug the power cord, wait for the whole machine to
cool, and place the heater stably.
[Note]
<Inspection method>
Insert the power plug into the socket and start for use; after about half an hour, turn off
and pull out the plug. Check whether the plug pins are hot; replace the socket if so (more
ing of the socket due to poor contact.
" to enter the standby state and
" to check the remaining
12
" and
As
" on the control pan-
-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis