Average opening degree.
Should only be changed by trained staff
Start-up time for signal reliability
Should only be changed by trained staff.
Stability factor for superheat control.
Changes should only be made by trained staff
Forced closing. AKV valve shut in pos. ON
Fan
Fan stop on compressor cut out
Delayed fan stop when compressor is cut out
Safety function. The fan stops if the S5 tem-
perature reaches this value
Miscellaneous
Delay of output signal after start-up
Define digital input signal (DI:
OFF=not used, 1=Door alarm, 2=defrost start,
3=Night operation, 4=External start/stop, 5 =
Coordinated defrost with cable connections,
6 = door function
Network address (range = 0-60)
ON/OFF switch (service-pin message)
Access code
Used sensor type for S3, S4 and S5 (Pt / PTC)
Set supply voltage frequency
Define digitalt output signal (DO:
0=not used
Coordinated defrost with cable connections:
1=Master, 2= Slave
Max. standby time after coordinated defrost
Display S4 % (S
)
out
0%=S3 (S
)
in
100%=S4 (S
)
out
The display temperature can be seen in u56
Manual control of outputs:
OFF=No override
1: Compressor reay is ON (railheat relay = ON)
2: Defrost relay is ON
3: Fan relay is ON
4: Alarm relay is OFF (Railheat relay = on)
5: DO output is ON
6: AKV output is ON
7: Light relay is ON (Railheat relay = on)
When manual control is terminated, the set-
ting must be changed to OFF
Pressure transmitter working range – min.
value
Pressure transmitter working range – max.
value
Inject-ON definition
When the ON input is cut out refrigeration is
stopped.
Here you define how the fan relay and the
alarm function are to act:
1 = Fan relay = ON, alarm monitoring active
2 = Fan relay = OFF, alarm monitoring active
3 = Fan relay = OFF, no alarm monitoring
4 = Fan relay = ON, no alarm monitoring
5 to 8= as 1 to 4, but without connection to
terminal 40-41.
Refrigerant setting
1=R12. 2=R22. 3=R134a. 4=R502. 5=R717.
6=R13. 7=R13b1. 8=R23. 9=R500.
10=R503. 11=R114. 12=R142b. 13=User
defined. 14=R32. 15=R227. 16=R401A.
17=R507. 18=R402A. 19=R404A. 20=R407C.
21=R407A. 22=R407B. 23=R410A. 24=R170.
25=R290. 26=R600. 27=R600a. 28=R744.
29=R1270. 30=R417A
Rail heat during day operation.
Setting of ON period in percentage of the
time in "o43"
EKC 414A1
n16
10%
75%
30.0
n17
5%
70%
30.0
n18
0
10
4
n36
OFF
ON
OFF
F01
no
yes
no
F02
0 min
30 min 0
50.0/
F04
-50.0
50.0
off
o01
0 sec.
600 sec 5
o02
OFF
6
0
o03
0
990
0
o04
OFF
ON
OFF
o05
OFF
100
OFF
o06
Pt
Ptc
0/Pt
o12
50 Hz
60 Hz
50
o13
0
2
0
o16
1 min
30 min 20
o17
0%
100%
100
o18
OFF
7
OFF
020
-1 bar
5 bar
-1
021
6 bar
36 bar
12
o29
1
8
5
o30
0
30
0
o41
0%
100%
100
Instructions RI8JN253 © Danfoss 05/2005
Rail heat during night operation.
Setting of ON period in percentage of the
time in "o43"
Rail heat
Time period for the aggregate ON/OFF time
Rail heat definition
0 = no rail heat relay
1 = alarm relay changed into rail heat relay
2 = compressor relay changed into rail heat
relay
3 = no function
4 = no function
5 = light relay changed into rail heat relay
Service
The following readouts can be performed via the belonging parameter
Defrost sensor S5 S
def
Status on DI-input
Defrost time
Air temperature S3 (S
)
in
Status on night operation (on or off )
Status on ON-input
Status on DO-output
Air temperature S4 (S
)
out
Thermostat temperature
Thermostat cut-in time
Temperature at S2
Superheat
Superheat reference
AKV valve's actual opening degree
Evaporating pressure
Evaporating temperature
Weighted S3/S4 temperature shown in the
display
Weighted S3/S4 temperature used by the
alarm function
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep both buttons depressed at the same time as you reconnect the supply voltage
o42
0%
100%
100
o43
6 min
60 min 10
o68
0
5
0
u09
°C
u10
u11
min.
u12
°C
u13
u14
u15
u16
°C
u17
°C
u18
min.
u20
°C
u21
K
u22
K
u23
%
u25
bar
u26
°C
u56
°C
u57
°C
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis