2.6 CIRCUIT DE COMMANDE ET DE PUISSANCE VERSION 'AW' (SUITE)
01
02
03
SONDE
D8 P3
P4 D9
13
14
1
3
THRMST AIR
OUT3
17
OUT2
OUT1
19
22
DESCENDANT
MONT ANT
DESCENDANT
21
20
24
23
18
D15
7
R4
D16
4
8
04
R4
5
10
11
05
S I CAPTEUR DE TEMPERATURE AIR
E XTERIEUR PAS INS TALLE, ENLEVER LA
LIAIS ON ET CONNECTER LA BORNE
AVEC LA BORNE Lo.
MOTEUR
DE VENTIL-
ATEUR
MOTEUR DE
REGISTRE
06
AIR NEUF
BOIT DE L' AIR NEUF (SI
07
N
L3
L2
L1
DISJONCTEUR
CONDENSEUR A
AIR 5A
VERS RELAIS
CONDENSE UR A AIR
N
W(C)
U(R)
COMPRESSOR
DISJONCTEUR VENTIL ATEUR MONOPHASE
MODELE
AA/AW600BVH X(F)
AA/AW900BVH X(F)
AA/AW1200BVHX(F)
COMMANDE A
DISTANCE OCC/INOCC
PONTER POUR UN FONCTI ONNEMENT NORMALE VOIR NOTE 2
10
11
NORTRONI C S
HOR LOGE
<PALADIN>
5
<3>
8
9
10-
3
OUT2
<2>
M
HUMIDISTAT
<1>
1
4
4
2
MONTANT
MONTANT
INOCCUPE
5
6
D5
D18
1
10
4
R5
10
10
7
11
R4
R13
11
11
9
R4
R12
(RCU)
6
(CONDENSER
A AIR)
VOY ANT
AUTO
CAPTEUR DE TEMP ERATURE
AIR EXTERIEUR. CONTACT
OUVERT S I TEMPERATURE
TROP BASSE
MAX
2(4)
1(2)
45
P(1)
MIN
L
43
Lo
N
44
TERRE
BORNES
VENT
COND
MOTEUR DE REGISTRE
NEUF D' A IR
INSTALLE)
(SI INSTALLE)
CIRCUIT D'ALIMENTATION EN 3 PHASE AVEC
VENTILATEUR A MONOPHASE
1
3
DISJONCTEUR
VENTILATEUR
PRINCIPAL
2
4
CIRCUIT DE
46
COMMANDE
A1
1
3
5
13
A1
1
3
2
4
6
14
A2
2
4
A2
23
2 4
17
18
S
L
N
R
C
MOTEUR DE
VENTILATEUR
COMPRESSEUR
DISJONCTEUR COMPRESSEU R
'F'
NON 'F'
VALEUR DE REGLAGE
LIMITE DISJONCTEUR
10A
4A
4.6A
3.8A
10A
6A
6.7A
5.6A
20A
20A
10.5A
8.8A
RELIER SI COMMANDE
A DISTANCE MONTEE
D11
P5
D10
P6
7
11+
R12
RCU
OUT1
N/O
1
VOYANT
4
DESHUM
2
3
D20
29
C
INTERRUPTEUR
L
H
INTERRUPTEUR
30
C
D23
D21
H
L
31
1
RE3
COMMUTATEUR 3 POS,
REGISTRE AIR NEUF
N/C
D24
7
R3
3
1
4
10
D25
R6
R6
11
9
7
11
D22
4
10
R7
7
11
CIRCUIT D'ALIMENTATION EN 3 PHASES AVEC
VENTILATEUR TRIPHASE
L3
L2
L1
5
1
3
6
2
4
CIRCUIT DE
VERS RELAIS
COMMANDE
CONDENSEUR A AIR
(RCU )
N
5
1
3
6
CONTACTEUR
VENTILATE UR
2
4
19
23
24
MOTEUR DE
VENTI LATEUR
DISJONCTEUR VENTILATEUR TRIPHASE
MODELE
'F'
AA/AW1500BVHX(F)
3.0A
Page 19
0-10VDC
+
P7
ALIMENTATION 12V
TERRE 0V
-
CAPTEUR TEMP AIR VARIENT
SELON FABRICANTS
9
R2
N/O
EN CONT INU
VENTILATEUR
6
3 2
A
7
EN CYCLE
RE1
33
HP
VENT ILATEUR
230 v
34
B
4
1
COR RUN
VENTILATION
BP
MISE EN MARCHE
PROGRESSIVE SI
INSTALLE OU
A RELIER
RE3
35
36
10
4
1
9
55
37
1
3
41
7
40
6
11
ELECTRO-
2
1
VANNE
THERMO-
DEGIVRAGE
STAT DE
DEGIVRAGE
4
4
3
TEMPORI S-
42
38
ATEUR
56
6 min
39
RE4
9
7
B
4
A
A2
A2
6
3
4
1
A
7
B
A1
A1
J
I
CON TACT SEC
VENTILATEUR
EN MARCHE
54
52
53
A
B
ELECTROVANNES
CONDENSEUR A
AIR (RCU)
5
1
3
5
6
2
4
6
46
A1
5
13
A1
1
3
5
CONTACTEUR
COMPRESSEUR
6
14
A2
2
4
6
A2
17
18
19
25
17
18
1 9
V(S)
U(R)
W(C)
S
C
R
COMPRESSEUR
SANYO COMPRESSEUR
COMPRE SSEUR
SEULEMENT
DISJONCTEUR COMPRESSEUR
VALEUR DE REGLAGE
VALEUR D E REGLAGE
LIMITE DISJONCTEUR
PAS 'F'
2.2A
14.4A
12.0A
SD4327350 EDITION 22
8