ADJUSTMENT OF THE POWER AND
OPERATIONAL TIMES
The power and operating times may be adjusted by means of 4
trimmers located on the control unit:
m
PLEASE NOTE: it is recommended that operating times
be set with the slow down function disabled (DIP 5 OFF).
m
WARNING: the adjustment of times has to be made
when the gate is still
MIN
MAX
POWER
30"
2"
90"
WORK
2"
120"
30"
2"
90"
PAUSE
2"
150"
CONTROL UNIT INDICATORS (LEDs)
The highlighted boxes indicate the state of the LEDs when the gate is resting.
LED
START
START P.
STOP
PHOTO
EDGE
Edge NO pressed: 8K2 between EDGE input and
mains
overload
POWER: potenza del motore
WORK: tempo di lavoro del
motore (2 ÷ 120 secondi)
PAUSE: tempo di pausa che
precede la richiusura automatica
(2 ÷ 150 secondi)
ON
START input closed
START P. input closed
STOP input closed
PHOTO input closed
EDGE input closed (edge not pressed)
EDGE input closed (edge pressed)
common (-)
Control unit powered-up
Accessory power supply overload
CABLE GLAND ASSEMBLY
The casing can accept 4 cable glands in the special easy-break
housings. The type of cable gland is indicated in the figure.
m
PLEASE NOTE:
• Remove the electronic circuit board before drill the casing.
• Drill the container using a suitably sized cutter, according to the
dimensions of the cable gland.
• Fix the cable glands using the special nuts.
PG9 - PG11
PG9 - PG11 - PG16
Standard edge
EDGE input open (edge pressed)
Resistive rubber edge
Control unit NOT powered-up
Accessory power supply within normal operational limits
- 11 -
OFF
START input open
START P. input open
STOP input open
PHOTO input open
EDGE input open (fault)