AC input
Maximum Output Charging Current
Max. Power
Efficiency
Battery Voltage to Trigger Sot Start Bulk Charge Mode
Soft Start Bulk Charge Current Level (Current Limit)
Protection:
Cooling System
Approvals
Dimensions
Specifications are subject to change and improvement without prior notice
WARNING
For indoor use only.
Explosion hazard: A battery being charged could emit explosive gases. Avoid smoking, open sparks or
naked flames in the vicinity of the battery being charged.
Danger of explosion and fire: While charging, explosive and flammable substances such as fuel or
solvents should not be kept in the vicinity of the charger or the battery. Do not cover the charger while
charging.
Danger of chemical burns: Battery acid is highly corrosive. lf your skin or eyes come into contact with acid,
immediately rinse the effected part of the body with excessive water and seek medical advice.
Do not charge a frozen battery or non re-chargable batteries.
Do not charge a damaged battery.
Before charging, make sure the input is within rating level, otherwise charging performance may be seriously
effected.
While connecting the charger to the battery, maintain the correct polarity connection and avoid short
circuiting the battery cables.
Disconnect the battery from the charger when the charger is not connected to the a/c power supply. This will
reduce back drain current.
Do not recharge non-rechargeable batteries. only charge batteries for which the charger was designed
During charging, the battery must be placed in a ventilated area.
The supply cord cannot be replaced. lf the cord is damaged the charger should be scrapped.
When charging automotive batteries: the battery terminal not connected to the chassis has to be
connected first. ( in most case this is the positive ). After charging, disconnect the battery charger trom the
mains. Then remove the chassis connection and then battery connection.
Warrantee: 2 year return to factory, see
address
www.sterling-power.com
100-240v 50/60hz 1.5 amp max
5A d/c for 12 v and 2.2 A d/c for 24 v
70 watts
>78%
6V < Vbat<10V
2.5 amps
Overload, Short Circuit ,
Over Temperature, Reverse Polarity,
No Spark Battery Connected and
Short circuit .
Natural Convection
CE EN55014 EN60335 EN50366
(L150 x W60 x D30 mm)
or
www.sterling-power-usa.com
for return