Do not remove any heater components yourself. Always contact your Zibro
dealer for repairs. When the power cord is damaged, it may only be replaced
by an authorised fitter. Use a new cord of the type H05 VV-F.
N
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste. Remove the batteries
from the remote control. Always start the new heating season with fresh fuel.
When you start re-using the heater follow the instructions again (starting from
section A and as specified).
O
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank ¶ from the heater and remove the fuel filter
(refer to Section M, Fig. M). Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
3
Place the transportation cap into the position of the fuel filter (Fig. N).
Press it tight. The transportation cap will, as much as possible, prevent oil
leakage from the heater during transport.
4
Always move the heater in an upright position.
5
Make the fixed tank empty with a fuel pump before transportation or in case
of wrong or dirty fuel. First remove the fuel filter and then insert the fuel
pump into the empty fixed tank. Follow the same procedure if the fuel tank
contains water.
P
SPECIFICATIONS
Ignition
Fuel
Capacity (kW) max.
Capacity (kW) min.
Suitable space (m
)
3
**
Fuel consumption (l/hr)
Fuel consumption (g/hr)
Burning time per tank (hr)
Capacity removable tank (litres) 7.6
Weight (kg)
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
* At maximum setting
electrical
Dimensions (mm)
paraffin
(including base plate) depth
4,00
1,05
Accessories
65-170
0,417
Mains
*
333
*
18,2
Electrical consumption igniter
*
11,5
Fuse rating
level (NDIR CO
2
** Specified values are indicative
width
height
manual fuel pump
transportation cap
-- AC/50 Hz
continuous
250V, 5A
-sensor E-Guard
).
2
4
435
315
437
230V
320 W
24W
83