SILENT-100 DESIGN Axial Extractor
Fans
The SILENT-100 extractor fan range is
manufactured to the high standards of
production and quality as laid down by the
international Quality Standard ISO 9001.
All components have been checked and
every one of the fi nal products will have
been individually tested at the end of the
manufacturing process.
On receipt of the product we recommend
that you to check the following:
1- That it is the correct model.
2- That the details on the rating label are
those you require: voltage, frequency...
The installation must be carried out in
accordance with the electrical standards
in force in your country.
This appliance is not intended for use by
young children or infi rm persons unless
they have been adequately supervised by
a responsible person to ensure that they
can use the appliance safely. Young chil-
dren should be supervised to ensure that
they do not play with the appliance
Installation
IMPORTANT: Before installing and wiring
the unit, ensure that the main supply is
disconnected.
Fig. 1:
1 : Protection grille
2 : Connection terminals
3 : Outlet with backdraught shutter
4 : Cable entry
The SILENT-100 is suitable for wall or
ceiling mounting and can either discharge
directly to the outside or via an individual
ducting system (see Fig. 2).
The unit can be mounted on the wall or
ceiling using the 4 rubber blocks and the
screws provided.
Make a hole in the wall or ceiling of
105 mm dia.
If the unit is to be installed with indivi-
dual ducting, use a standard 100 mm
dia. duct.
Ensure that there are no obstructions
to the airfl ow and that the impeller
turns freely.
Fix the extractor to the wall in such a way
that it is not distorted in order to avoid
noise generation or problems with the
rotation of the impeller. Make sure that
the backdraught shutter opens freely
and has not being damaged in transit.
Introduce the mains cable through the
cable entry (4) and fi x it to the wall.
Connect the electrical wiring as set out
below and then mount the protection
grille (1).
Electrical connection
The SILENT-100 is an extractor designed
for a single phase supply, with voltage
and frequency as indicated on the
rating plate of the unit. The units are
manufactured with double electrical
insulation
(Class II) and therefore they do not need
an earth connection.
The electrical installation must include
a double pole switch with a contact
clearance of at least 3 mm.
The electrical cable must enter the SI-
LENT-100 through the cable entry (4).
Once the cable has been introduced pro-
ceed using the electrical wiring diagram
applicable to the selected model.
SILENT-100 CZ DESIGN
For these models use the following
diagrams:
Fig.3: Switching the extractor through
the light switch.
Fig.4: To switch the fan through an
independent switch.