technical service for this procedure.
"S
"
EALED
SERIES STOVES
For "Ermetica" series pellet stoves a special
gas and duct the combustion air from the outside
(Fig. 5.5 A, B=Air intake C, D=Flue gas outlet).
5.5.1 Discharge through roof using a traditional
chimney
be made in accordance with standards UNI 10683
- EN 1856-1-2 - EN 1857 - EN 1443 - EN 13384-
1-3 - EN 12391-1 both as regards the dimensions
and the construction materials used.
DAMAGED chimneys made from unsuitable
material (asbestos cement, galvanised steel,
etc.... with a rough and porous inside surface)
are prohibited by law and affect proper stove
operation.
traditional chimney (Fig. 5.8) as long as the
following rules are observed:
- check the conditions of the chimney; old chimneys should
be renovated by introducing steel piping with
suitable insulation (rock wool, vermiculite).
only if the latter has a maximum cross-section
of 15 × 15 cm or diameter of 15 cm and features
an inspection opening.
For larger chimneys, suitably insulated steel
pipes need to be inserted on the inside (diameter
according to the length) (Fig. 5.9).
Makes sure connections to brick chimneys are
suitably sealed.
Avoid contact with combustible materials (e.g.
wooden beams).
available on the market.
1) Vermiculite and/or rock wool.
2) Steel pipes.
3) Closure panel.
cod. 00 477 2290 - 04/2015 - Palazzetti - PN - Italy
INSTALLATION
A) Chimney pot with wind protection
B) Maximum cross-section of 15 × 15 cm or diameter of
15 cm and maximum height of 4- 5 metres
C) Seal
D) Inspection
1
2
3
39