ensure controlled, reliable operation of this device when exposed to typical levels of electromagnetic interference as well
as ensuring that this device is not the source of emissions that might interfere with other equipment installed nearby.
NOTE: Per 30 CFR 75.320(b), the product tests for oxygen deficiency of MSHA-approved oxygen detectors compatible
with the product that can detect 19.5 % oxygen with an accuracy of ± 0.5 %.
NOTE: Per 30 CFR 22.7(d)(2)(i), the acceptable limit during calibration and bump testing with 2.5% methane must be
10% for MSHA-approved instruments using Industrial Scientific certified calibration gas.
NOTE: This product has an internal pump that controls the flow of gas delivered to the system. As a result of the
internal pump, a demand-flow regulator must be used in conjunction with this product.
Care and Operating Guidelines
Use the following guidelines to enhance personal safety and protection of the docking station and working environment.
The unit should be serviced by qualified personnel only. Contact Industrial Scientific for examination or repair.
To reduce the risk of electric shock or fire:
Do not use the unit during an electrical storm without proper protection.
Do not connect or disconnect any cables to or from the unit during an electrical storm.
Do not expose the unit to rain or moisture.
Do not push any objects into the openings of the unit.
To help protect the unit from sudden, transient increases or decreases in electrical power, use a surge suppressor, line
conditioner, or uninterruptible power supply (UPS).
To avoid possible damage to the unit's system board, wait 5 seconds after powering off the unit before restarting.
To avoid shorting the unit when disconnecting a network cable, first unplug the cable from the unit, and then from the
network jack. When connecting a network cable, first plug the cable into the network jack, and then the other end into the
unit.
Be sure nothing rests on the unit's cables or tubing. Ensure cables and tubing are not located where they can be stepped
on, cut, tripped over, loosened, or disconnected.
Do not place the unit on or near flammable materials.
The unit is equipped with a fixed-voltage power supply and will operate at only one voltage (see the regulatory label on the
outside of the unit for its operating voltage).
Do not use corrosive chemicals or vapors near the unit.
Do not immerse the power cable or plug in water.
Do not drop the unit.
Before cleaning the unit, disconnect the power supply from the power source.
Clean the unit with a soft cloth dampened with water.
Do not spray water directly onto the unit.
Do not use liquid or aerosol cleaners, which may contain flammable substances.
Compressed gas cylinders and their contents may present specific hazards to the user. Use only in a well-ventilated area.
Use only in accordance with the instructions and warnings as marked on the cylinder and the appropriate Material Safety
Data Sheet (MSDS).