1.
Gearcase protector

Replacing the blade

1. Holder A
1. Shaft bolt,
2. Bolt guard
1. L-wrench.
2. Output shaft
3. Holder B
4. Blade
5.
Clean the shaft thoroughly in solvent and dry with a clean
shop towel.
6.
Coat the entire length of the shaft with lithium-base grease.
7.
Reinstall the flexible shaft.
8.
Reinstall the bushing. Push it into the outer tube until it bot-
toms against the collar on the flexible shaft.
Inspect the gearcase protector
The metal gearcase protector is installed to protect the gearcase
flange from damage when working close to sidewalks or other
abrasive surfaces, and should be routinely inspected for damage
or excessive wear.
When replacing the protector, inspect to be sure that both of the
protector mounting screws are firmly tightened and each screw is
locked in place with a nut as shown.
1.
Align the hole in holder A with the matching hole in the gear-
case and then use a L-wrench to temporarily lock the output
shaft.
Always wear gloves when handling the blade.
2.
Loosen the shaft bolt then remove the shaft bolt, holder B
and the blade from the gearcase.
3.
Mount the blade and holder B onto the shaft, and then install
the bolt guard and shaft bolt (turn bolt counterclockwise to in-
stall).
4.
Align the hole in holder A with the matching hole in the gear-
case, and then use a L-wrench to temporarily lock the output
shaft.
5.
Firmly tighten the shaft bolt. Remove the L-wrench.
15