Technical Data - Oxyturbo OXYLASER IRON Gebrauchs- Und Wartungsanleitung

Lötbrenner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
INSTRUCTIONS FOR USE AND MAINTENANCE
GB
CAUTION
Read the following instructions carefully before using
the blowlamp and keep them for future reference.
The instructions supply all the information necessary
for correct use of the appliance to avoid danger and
damage.
OXYTURBO is not responsible for any damage occuring
due to incorrect use of the appliance, or to modifications
made to it.
PARTS LIST
1. Lower cartridge support
1a. Iron cartridge holder
2. Seal gasket
3. Upper cartridge support
3a. Metal spring to fix the cartridge
4. Adjusting knob
5. Handgrip
6. Injector
7. Air regulating ring
8. Burner ø 21
9. Flat flame burner
10. Copper welding tip
11. Cercoflam
12. Ignition knob
13. Holding clasp
14. Piezoelectric ignition electrode

TECHNICAL DATA

OXYLASER
505000
OXYLASER IRON
525000
Maximum operating
temperature
1.750 °C
Piezoelectric ignition
-
Accessories
Flat flame
burner
optional
Copper welding tip
optional
Cercoflam
optional
Injector Consumption
Burner ø 21
0,28 mm
Cercoflam
0,28 mm
Caution! It is not possible to fit the accessories to the
model with piezo ignition.
1. GAS SUPPLY
This blowlamp is fed by a 190g pierceable, butane gas
cartridge complying with EN 417 - type 200.
570800
570702
570905
505100
505030
525100
1.750 °C
1.750 °C
-
-
-
-
73 g/h
73 g/h
12
We recommend using the OXYTURBO cartridge, model
Butan 190g cod. 483000.
i
CAUTIONS
The use of other cartridges may be dangerous.
Do not use dented cartridges.
Remove any labels or dirt from the piercing point and
the seal on the dome.
2. PUTTING INTO SERVICE
2.1 INSERTING OR CHANGING THE CARTRIDGE
-
Make sure the blowlamp valve is closed, turn the
adjusting knob (4) clockwise.
Blowtorch with plastic cartridge holder
-
Completely unscrew the lower part (1) (fig.1).
-
Fit a new gasket (2) if damaged or missing.
-
Insert the new cartridge (fig.2).
-
Re-tighten the lower cartridge support all the way (1)
(fig.3).
Blowtorch with iron cartridge holder
-
Completely unscrew the handgrip from the iron cartridge
holder
-
Fit a new gasket (2) if damaged or missing.
-
Remove the metal spring from the bottom of the cartridge
holder
-
Insert the new cartridge.
-
Insert the metal spring in the bottom of the cartridge
holder to fix the cartridge.
-
Completely screw the handgrip on the iron cartridge
holder (1a).
i
CAUTIONS
Changing or inserting the cartridge must be
performed in a well ventilated area, preferably
outdoors away from inflammable materials or
substances and from glowing sources of heat (such as
naked flames, lit cigarettes, electrical rings, etc.) far
away from persons or animals.
Make sure the cartridge is empty before changing it
(see 5.4).
Do not use the blowlamp if the gasket (2) is damaged
or missing (see 5.3).
To protect the environment, dispose of the cartridge
in a safe place and preferably in a recycling bin.
3. INSTRUCTIONS FOR USE
3.1 SWITCHING ON
Blowlamp with piezoelectric ignition
-
Turn the adjusting knob (4), one turn in an anticlockwise
direction.
-
Immediately press the ignition button down until the gas
leaving the burner ignites.
Blowlamp with normal ignition
-
Turn the adjusting knob (4), one turn in an anticlockwise

Werbung