Before using
Note
Operation temperatur range
Maximum cooling
DB/WB (°C)
35/24
Check up whether the exhaust hose has
been mounted properly.
Cautions for cooling and dehumidifying
operations:
-When using functions on cooling and
dehumidifying, keep an interval of at least
3 minutes between each ON/OFF.
-Power supply meets the requirements.
-The socket is for AC use.
-Do not share one socket with other
appliances.
-Power supply is AC220-240V 50Hz
2.AUTO MODE
- According to the current room
temperature, automatically select the
mode cooling, dehumidifying or fan (see
table 1).
Table 1
Room (Temperautr) Tr
23°C≤26°C
Mode
Dehumidify
Set temperature
23°C
3. Cooling operation
-Press the "Mode" button till the "Cool"
icon appears.
-Press the " DOWN "or" UP "button to select
a desired room temperature. (16°C-31°C)
-Press the " WIND " button to select wind
speed.
4.Dehumidifying operation
Press the "Mode" button till the
"Dehumidify" icon appears .
-Automatically set the selected
temperature to current room temperature
minus 2°C. (16°C-31°C)
-Automatically set the fan motor to LOW
wind speed.
5. Fan operation
-Press the "Mode" button till the "Fan" icon
appears.
-Press the " WIND " button to select wind
speed.
6. Timer operation
Timer ON setting:
-When the air-conditioner is OFF, press the
"Timer" button and select a desired ON
05
time through the temperature and time
setting buttons.
Minimum cooling
-"Preset ON Time" is displayed on the
18/12
operation panel.
-ON time can be regulated at any time in
0-24 hours.
Timer OFF setting
-When the air-conditioner ON, press
"Timer" button and select a desired OFF
time through the temperature and time
setting buttons.
-Preset OFF Time" is displayed on the
operation panel.
-OFF time can be regulated at any time in
0-24 hours.
7. SWING(air flow)
After machine turns on, press this key, the
louver will swing continuously left and
right; by pressing this button again the
movement will stop and the louver remain
in that position.
8. SILENCE CONTROL FUNCTION
- While in cooling mode, press the SILENCE
key. The machine will be turned to low
26°C
speed to reduce machine noise.
Cooling
25°C
- Press the SILENCE key again can cancel
the setting.
9. Drainage
Internal Tank Water Full Alarm Function
The inner water tank in the air-conditioner
has one water level safety switches, it
controls water level. When water level
reaches an anticipated height, the water
full indicator lamp lights up. (If water pump
is damaged, when the water is full, please
remove the rubber blockage at the bottom
of unit, and all water will drain outside.)
CONTINUOUS DRAINGE
-When you plan to leave this unit unused
for a long time, please remove the rubber
blockage from the drainage hole at the
bottom of unit, and connect a drain hose
to the lower fixing clip. All the water in the
water tank will drain outside.
-You can drain the water as the above when
the unit working at the HEAT mode.
-If water pump is damaged, continuous
drainage can be used, and under this
condition, the water pump is not activated.
The unit can also work well.
-If water pump is damaged, intermittent
drainage can also be used. Under this
Operating Instructions
condition, when the water full indicator
lamp lights up, please connect a drain hose
to the lower fixing clip, then all the water in
the water tank will drain outside. The unit
can also work well.
1 Installation Explanations:
-A removal air-conditioner shall be installed
in the flat and empty place all around.
Don't block the air outlet, and the required
distance around should be at least 30cm.
(See Fig.8)
-Should not be installed in dry cleaner.
-Socket wiring should be in accordance
with the local electric safety requirements.
Installation Explanations