5.5.3.2 Fixing with corner adapter

Fix the wall bracket to the corner mount adapter
using 4 washers, 4 stainless steel grower washers
4 hexagon stainless steel bolts (A4 class 80)
M10x30mm.
Fig. 8
Make sure the thread are free of dirt and debris.
Apply a generous amount of threadlocker (Loctite
270) on the 4 threaded holes on the corner module.
Tighten the screws.
Pay attention to the fixing. Tightening
torque: 35Nm.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.
Document 800-23313 Rev. A

5.5.4 Sunshield mounting

Remove the protective film before the
sunshield installation.
Fix the sunshield to the housing using screws and
washers provided.
Apply a generous amount of thread locking
compound (Loctite 270) into the threaded holes in
the base of the device.
The thread compound must cure for one hour, allow
for this period prior to completing the installation.
Fig. 9