Terminals

WARNING OUT Terminal

This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a pulse signal from WARNING
OUT terminal.
COM terminal
Tape recording stops.
Note
To turn the clog detection function off, set CLOG
DETECTION to OFF on the ALARM SET menu.
44
WARNING OUT terminal
5 V
0 V
To reset, press STOP x or
EJECT Z, if the clog detection
function works and the VCR
gives warning, otherwise, press
the reset button.

TAPE END OUT Terminal

When the VCR detects the tape end or the time counter
shows "3H" during recording, the output level
becomes 0 V DC. To resume the 5 V output, press the
operation button (EJECT Z, REC z, FF M,
REW m or PLAY B, etc.).
TAPE END OUT terminal
REC mode
Tape end
Beginning of tape
Recording
Rewind
mode
Output
signal
REPEAT REC mode
Tape end
Recording
Rewind
mode
Output
signal
2 sec.
Set TAPE END WARN. to COUNTER or TAPE END
on the ALARM SET menu.
• COUNTER: the time counter shows "3:00:00" and a
signal is output from the TAPE END OUT terminal
(recording will be continued to the end of the tape).
• TAPE END: the VCR detects the tape end.