INTRODUCTION
AVM™2 (Automatic Vacuum Management) is a control unit for vacuum ejectors. This manual is specific for
AVM™2 but it also shows the interfaces to the ejector platforms in Piab's product range where AVM™2 may
be used. For more detailed information on the vacuum ejector, please see the manuals for the respective
ejectors.
FUNCTIONS/FEATURES
Valve (V1) for ON/OFF of the ejector. This valve is normally open (NO) or normally closed (NC). Special
function: the normally closed (NC) valve behaves as normally open (NO) if the power is turned off, i.e., the
ejector continues operating.
Valve (V1) for ON/OFF is also available as a NC 2 version. The NC 2 valve behaves like a NC (Normally
Closed) even if power to AVM™2 is turned off.
Valve (V2) for ON/OFF of the blow-off function.
Option for valve (V2) - automatic blow-off (1 sec), activated immediately after valve (V1) has changed
position.
Adjustment valve (V3) for controlling the blow-off flow.
Integrated automatic energy-saving function (ES) used to minimize the air consumption. This function can
be activated manually or by a signal.
Vacuum switch that sends two digital output signals, S1 and S2. Selection of signal level is done with a
rotary switch, and there are 16 preset signal levels available.
LEDs that show the status of valves and vacuum signals.
LED display that shows the current vacuum level in -kPa or -inHg in the normal position.
On AVM™2 units for P6010, there is an option to blow from a separate port to maximize blow-off
efficiency in the vacuum system.
Integrated non-return valve. Maintains vacuum in the system in case of compressed air or electricity
failure.
DESIGN
Modular in two separate main sections, one electronic unit and one valve unit.
Design that maximizes the blow-off efficiency.
Protective covers against dust and humidity, IP65 [NEMA 4].
Compact and slim design.
M12 8-pin electric connection. Suitable cables are available as accessories.
Simple setting of desired signal levels for vacuum via a rotary switch. S2 is always the deeper vacuum
level as compared to S1.
PNP or NPN is selectable via contacts pins.