Symptoms:
Leaks in the joints of
the lance
There's air
appearing in the
hose or liquid
stream is being
interrupted
Not possible to
reach the maximum
pressure
In case of other symptoms preventing proper operation of the
We offer technical support and on-line help: serwis.marolex.pl
Removal and Disposal
Pb
Reason:
Lost R47c seal or loose
nozzle nut R64
Unsealed or incomplete
system of the telescope
lance
In the pump there is air
mixed with a liquid (too
little liquid or tilted
sprayer
Dirty sieve R322
Dirty pressure pump
sprayer please contact MAROLEX service at:
serwis@marolex.pl
Solution:
Insert the seal R47c or tighten the
nozzle nut
Tighten or repair the telescope
system in the lance
Repeatedly turned on and off the
sprayer by pressing the switch button
or add the liquid to the container
Clean the sieve R322
Contact Marolex service:
serwis@marolex.pl