TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE REASON
The pump
1. Nozzle worn.
does not
2. Nozzle clogged.
operate
3. Water filter dirty.
at the
4. Water is low.
prescribed
5. Air being sucked into the
pressure.
system.
Sudden
6. Air in pump.
changes in
7. Adjustable nozzle posi-
pressure or
tioned incorrectly.
low spray
8. Vacuum lock due to air vent
pressure.
clogged.
9. Water temperature too high.
The motor
1. Problems with Automatic
buzzes but
Shutoff device.
fails to start
2. Portable pressure cleaner
or motor
in disuse for a long time.
does not
3. Pressure needs to be
start at all.
relieved.
Water
1. Worn seals.
leakage.
2. Hose connector not fully
engaged.
3. Dirty hose inlet.
Motor
1. High pressure system or
starts or
pump hydraulic circuit not
continues
watertight.
to run even
2. Air in system.
though the
3. Tank empty.
trigger is
4. Base filter is clogged.
released.
POSSIBLE SOLUTION
1. Replace nozzle.
2. Clean nozzle.
3. Clean filter.
4. Add water to tank.
5. Add water to tank.
6. Purge air from system.
7. Adjust nozzle.
8. Clean air vent located in cap.
9. Reduce temperature - cold water
only.
1. Please contact nomad2go@tti.
com.hk for service instructions.
2. Please contact nomad2go@tti.
com.hk for service instructions.
3. Squeeze trigger and release
pressure.
1. Please contact nomad2go@tti.
com.hk for service instructions.
2. Check connection.
3. Rinse/remove obstruction.
1. Please contact nomad2go@tti.
com.hk for service instructions.
2. Purge air from system.
3. Fill with water.
4. Clean filter.
20