WIND SENSOR

Press SELECT until the selected area icon
top right display area.
Wind speed: Gently rotate the wind vane and confirm
a numerical reading on the base station, e.g.,
Wind direction indicator. Move the direction of the
wind indication and verify the icon moves in the same
direction
.

TEMPERATURE / HUMIDITY SENSOR

1. Press SELECT until the selected area icon
the bottom left display area.
2. Press UP / DOWN to select channel 1
a numerical reading.

RAIN GAUGE

1. Press SELECT until the selected area icon
the middle right display area.
2. Press MODE until
3. Tilt the tipping funnel on the rain gauge several times
and verify a numerical reading on the base station.
TIP If no reading is displayed for a sensor, press the
SEARCH button on the base station to initiate a wireless
sensor search.

MOUNTING / PLACING OF SENSORS

WIND SENSOR
NOTE The sensor should be positioned in an open area
away from trees or other obstructions.
a
Secure the sensor connector in the desired location:
is in the
is in
and verify
is in
is displayed.
b
a. Align the back of the sensor connector to an existing
pole. Secure in place by inserting the ends of the
U-bolt into the holes on the sensor connector and
securing it with washers and bolts.
OR
b. Insert 4 type A screws into the holes of the sensor
connector. Screw firmly into place, i.e., fence.
Slide wind vane onto the smaller end of the sensor
connector.
.
IMPORTANT Ensure that the wind sensor is pointing
North to enable it to record accurate readings.
TEMPERATURE / HUMIDITY SENSOR
TIP Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not
more than 1.5 m (5 ft) and which can shield it from direct
sunlight or wet conditions for an accurate reading.
Secure the sensor in the desired location using the wall
mount bracket or table stand.
RAIN GAUGE
The base station and rain gauge should be positioned
within an effective range: about 100 meters (328 feet)
in an open area.
The rain gauge should be mounted horizontally about 1
meter (3 feet) from the ground in an open area away from
trees or other obstructions to allow rain to fall naturally
for an accurate reading.