Herunterladen Inhalt Inhalt Diese Seite drucken

All-In-One Sensor; Installation; Assemble The Wind Sensor; Remove The Tape On The Debris Collector - Oregon Scientific WMR500 Bedienungsanleitung

Professional all-in-one weather station
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
B Wind speed/Wind direction/ Wind chill area
4
3
SPEED
AVG
2
GUST
kph mph m/s knots
1
LIGHT
MODERATE
STRONG
STORM
1. Wind speed level indicator
2. Wind speed indicator (AVG/GUST)
3. Wind speed reading (m/s, knots, kph or mph)
4. Today max wind speed memory
5. Wind direction indicator
6. Today minimum wind chill
7. Wind speed level description
C UVI/ Rainfall area / Barometric pressure / Air quality area
4
5
6
3
PAST24hrs TODAY MAX
UVI
2
mm
in/hr
1
LOW MED V.HI EX.HI
1. UVI level indicator
2. UVI/rainfall reading (UVI; mm; inch; mm/hr; in/hr)
3. Today/Past 24 hours rainfall
4. Rainfall/rain rate indicator
5. UVI indicator
6. Current/Max UVI or rain rate
7. Barometric pressure trend
8. Barometric pressure indicator
9. PM (Particle Matter) reading indicator
10. AQI (Air quality index)
11. Barometric pressure unit (mb/hPa/mmHg/inHg)
12. PM2.5/PM10 unit (μg/m
/ppm)
3
13. AQI level indicator
14. Barometric pressure /PM reading
D Clock /Calender/Weekday/Moon Phase area
1
1. Clock
2. Date
3. Weekday
4. Moon phase
P/N: 300103876-00001-10 Rev1.0
4/70
WMR500_EN R25.indd 3
TODAY
MAX
WIND CHILL
TODAY
MIN
7
8
9
10
PM
PM
AQI
2.5
10
mbhPa
11
mmHg
inHg
µg/m³
12
ppm
13
14
2
3
4

ALL-IN-ONE SENSOR

1
5
6
7
7
1. Wind speed sensor: Measures wind speed
2. Level indicator: Indicates whether the sensor is level or needs adjustment
3. Rain gauge with collector: Takes rainfall readings/ Collects rain
4. UV sensor (not included) location: Take UV readings
5. Solar panel: Provide power to the sensor and prolongs battery life
6. Wind direction vane: Takes wind direction
7. Temperature/Humidity sensor: Measures temperature and humidity readings
8. Dust sensor (not included): Take PM 2.5/PM 10 readings
9 10
11
17
16
9. SET NORTH: Calibrate the direction of wind sensor
10. RESET: Returns unit to default settings
11. Battery compartment for the all-in-one sensor
12. Temperature/Humidity sensor location
13. Dust sensor location (optional)
14. Debris collector
15. Screw to open/close the debris collector
16. Battery compartment for dust sensor (optional)
17. CHANNEL 1, 2, 3: Select sensor channel

INSTALLATION

ASSEMBLE THE WIND SENSOR

1. Loosen the screws in the wind cups and wind vane.
2. Insert the top of the wind sensor unit into the wind cups securely with some
pressure and then twist the screw tightly.
3. Insert the bottom of the wind sensor unit into the wind vane securely with some
pressure and then twist the screw tightly.

REMOVE THE TAPE ON THE DEBRIS COLLECTOR

A debris collector is located under the rain collector and fixed by fiber tape. Unscrew
it and remove the tape before first time using.
3
12
13
15
14
2017/3/14 下午2:50
2
3
4
5
6

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis