8.

Maintenance

Although TPS does not need periodical maintenance, a functional check with every facility maintenance check is
strongly recommended.
8.1.

Periodic functional test

The periodic functional test should consist of the following:

Test the reopening function over the whole object area.

Confirm sensor is fastened securely

Ensure the front window / lenses of TPS are clean and without scratches
8.2.

Cleaning

Clean the front surface from dust or dirt with a soft towel. To clean the surface with a towel, it must be either dry
or slightly moist, but should not be wet.
Do not use plastics cleaner, acetone, gasoline or other solvents!
9.

Troubleshooting

Trouble
Cause
Irregular supply voltage
Does not operate
Wire / cable cut or improperly
as expected
connected
Inappropriate installation
The red LEDs
Trigger level too low
remain unlit
TPS installed too high
Dirty lens
Irregular operation
Something swaying between the
sensors interrupts the light beam
The red LEDs blink
Trigger level set get too long
continuously
TPS installed too low
The red LEDs
Minimum gap between devices
flicker continuously
too short
The device is interrupted by other
infrared emitters
Adjusting trigger
Beams are interrupted by a hand
level (screws) has
(LEDs always on)
no effect
Trigger level too long (LEDs
always off)
Direction
Wrong TPS device
recognition
functions poorly in
Sensor incorrectly set
both directions
Direction
recognition
The two triggers do not have the
functions poorly in
same level
one direction
Other trouble
Root cause not known
© CEDES/November 2012
Solution
Adjust to the specified voltage range
Check the wires / cable: Reconnect or replace as
appropriate
Check the installation section (Chapter 5) of this manual
Increase the trigger level
Check the installation section (Chapter 5) of this manual
Clean the front surface from dust or dirt with a soft towel
Remove the obstruction
Decrease the trigger level
Check the installation section (Chapter 5) of this manual
Increase gap between devices
If possible, change the alignment angle of the sensors
Take care that while manually adjusting the trigger level
with a screwdriver, the light beams are not interrupted
by your hand
Try to pull the screw a bit while tightening
Check the label for right TPS device
Adjust the trigger to the same level
Adjust the trigger to the same level
Contact your CEDES representative