Example for trigger adjustment:
The TPS device is mounted at the top to detect
objects from above. To detect the higher object, the
trigger level has to be set between the height of two
objects.
The trigger level can be calculated according to
s
trigger
Figure 5: Example for triggering the TPS device
5.

Installation


Be sure to turn off power supply when
carrying out electrical work.

Clearly mark that this device is out of
service.
There are one flush and two surface mounting
solutions. Distances from wall, doors and/or other
obstacles must be considered. The application of
multiple (adjacent) TPS sensors requires a minimum
gap between the devices. This gap is needed to
avoid
any
interference
sensors.
Important information:
Every device needs to be separately connected to
the corresponding control device. For electrical
connection, see Figure 10.
© CEDES/November 2012
= s
– s
mount
height
Objects in the range from the
trigger level up to the minimal
operating range are detected
by the TPS
Objects in the range from the trigger
level down to ground are not detected
by the TPS.
between
neighboring
s
wall
Figure 6: Spacing for TPS front view (left) side view (right)
s
Spacing to wall
wall
s
Spacing to next TPS
gap
s
Spacing to door
door
5.1.

Flush mounting

Figure 7: Backside view of a flush-mounted TPS
1. Mill square (the sheet has to be thinner than
2 mm)
2. Drill holes
3. Mount sensor with countersink
4. Connect wires (see Figure 10)
5. Set trigger level (see Figure 4)
6. Clip window to sensor
www.cedes.com
s
door
s
gap
> 0.1 m
> 0.2 m
> 0.1 m
(All dimensions in mm)
TPS
5