10. Technical data

Sensor
Type
Light beams
Detection levels
Outputs (A or B)
Direction recognition
Test input
Optical
Technology
Operating range
Trigger level
Distance detection accuracy
Distance detection hysteresis
Light beam diameter
Max. ambient light
Mechanical
Dimensions (w x h x d)
Housing material
Enclosure rating
Connection
Cable
Temperature range
Electrical
Supply voltage U
Max. current consumption at 24 VDC
Max. output load
Beam indicator
Output puls duration
(TPS 210 only)
General
Eye safety norm
EMC emission
EMC immunity
Vibration
Shock
RoHS
Certificate
10
SP
www.cedes.com
Installation and operation manual
TPS 200
TPS 100
2
2
2
2
2 (PNP)
1 (PNP)
No
No
No
Yes
Two beam infrared triangulation sensor
0.1 ... 2 m
0.3 ... 2 m
±5 mm at 0.5 m with Kodak white and gray test card
±10 mm at 1 m with Kodak white and gray test card
±20 mm at 2 m with Kodak white and gray test card
< 2% with Kodak white test card
22 mm
100,000 Lux
150 x 48 x 26 mm
Polycarbonate (PC), black
IP65
Standard: 4-pin M8 connector, male
0.15 m pig-tail, incl. connecting cable 5 m
-40 °C ... +60 °C
10 ... 30 VDC
40 mA
50 mA, max. 100 nF
Two red LEDs, one red LED for each light beam
200 ms
EU Directive 2006/25/EG Annex I
EN 61000-6-3
EN 61000-6-2
EN 60068-2-6
EN 60068-2-27
2011/65/EU
CE
TPS 210
2
1
2 (PNP or NPN)
Yes, max. 5 m/s with
0.2 m wide object
No
© CEDES/November 2012