TPS
5.2.
Surface mounting - cable invisible
Figure 8: Backside view of a surface-mounted TPS
1. Drill holes
2. Lead connector through the hole
3. Mount sensor with screws (recommended
screws are flat headed torx)
4. Connect wires (see Figure 10)
5. Set trigger level (see Figure 4)
6. Clip window to sensor
5.3.
Surface mounting - cable visible
Figure 9: Backside view of a surface-mounted TPS
1. Drill holes
2. Cut slots from sensor on the back side.
3. Lead connector through the slots
4. Mount sensor with screws (recommended
screws are flat headed torx)
5. Connect wires (see Figure 10)
6. Set trigger level (see Figure 4)
7. Clip window to sensor
6
(All dimensions in mm)
(All dimensions in mm)
www.cedes.com
Installation and operation manual
5.4.
Electrical installation
Standard M8 male connector
Pin allocation based on industry standard:
Pin 1: +U
Pin 2: PNP or NPN Output B (black)
Pin 3: GND (blue)
Pin 4: PNP or NPN Output A or test
input (white)
Top view of the connector (view to the pins)
Figure 10: Connecting diagram of the connector
1. Connect the sensor to connecting cable
2. Connect the wires in the control device
according to pin allocation
(brown)
sp
© CEDES/November 2012