OJ Microline OTD2 series Handbuch Seite 8

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Type OTD2 with wireless IR floor sensor
The green LED will flash twice while the signal is being received
from the IR sensor. Once the signal has been received,
longer flash on the display. Press the programming button to accept
the additional IR sensor and the display will show the measured
temperature from the IR sensor.
Replacing an IR sensor
If necessary, an IR sensor can be replaced and the thermostat must
be configured for the new IR sensor.
Press and hold the programming button for 3 seconds.
will be shown on the display. Press the programming
button several times until
display.
Press the up or down button to set the thermostat in learning mode.
The display will flash:
Press the connect button located under the cover of the new IR
sensor.
See figure 4.
The green LED will flash once for IR1 or twice for IR2 while the
signal is being received from the IR sensor. Once a signal has been
received, the display will stop flashing. Press the programming button
to accept the new IR sensor. The temperature recorded by the sensor
will then be shown on the display.
Removing IR sensor 2
If IR sensor 2 is removed, the data for the sensor in the thermostat
have to be deleted.
Press and hold the programming button for 3 seconds.
Press the programming button several times until
shown on the display. Press both arrow buttons simultaneously for
3 seconds to delete the setup for IR2. Then press the programming
button to confirm that IR2 has been removed.
8
will no
or
is shown on the
is
The trademark is registered and belongs to OJ Electronics A/S · © 2013 OJ Electronics A/S
IR sensor status readout
If an IR sensor is added the thermostat, a readout of which IR sensor
is connected to the thermostat can be done. Press and hold the
programming button for 3 seconds.
on the display. Press the programming button several times until
is shown on the display. Press the programming button
to display the floor temperature recorded by IR sensor 1. Press the
programming button again to display the floor temperature recorded
by IR sensor 2 (if present).
Wireless signal fault
If the signal between the thermostat and IR sensor disappears
for more than 20 minutes, the thermostat will automatically enter
Regulator mode, the display will read 3.0 and the red LED will flash.
The thermostat now acts as a simple controller without temperature
sensor. The heating system is regulated on a scale from 0.0-10.0,
corresponding to 0-100% of heat output. The factory setting is 3.0
(30%). Once the signal returns, the thermostat automatically reverts
to normal temperature control.
Fault codes:
E1 - IR sensor signal fault. Replace the battery in the IR sensor.
LED flashes red once.
E5 - Overheating. Excessive thermostat temperature. Heating is
switched off. LED flashes 5 times.
Environment and recycling
Please help us to protect the environment by disposing of the
packaging in accordance with the national regulations for waste
processing.
Recycling of obsolete appliances
Appliances with this label must not be disposed of with the
general waste. They must be collected separately and
disposed of according to local regulations.
English
English
will be shown