Herunterladen Diese Seite drucken

OJ Microline OTD2 series Handbuch Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Type OTD2 with wireless IR floor sensor
OTD2 is an electronic thermostat with wireless IR sensor for
installation in a standard wall box. The wireless IR sensor accurately
measures the surface temperature of the floor and the room
temperature. It transmits the recorded signals to the thermostat,
which controls the heating element in accordance with the selected
temperature setting.
The IR sensor can be mounted directly on a wall at a distance of up
to 15 metres from the thermostat. The thermostat allows the required
temperature to be set within the range 0-40°C. An LED indicates that
heating is active.
Both the thermostat and IR sensor are suitable for GIRA system 55
and for ELKO or NORWESCO frames.
PRODucT PROGRAMME
OTD2-1655
White
OTD2-1655-E2
Anthracite/alu
OTD2-1655
cE MERkING
Applied standards:
EN 61000-6-3, EN 61000-6-2, EN 60 730-1 and EN 60730-2-9.
The product may only be used if the complete installation complies
with relevant directives. The thermostat may only be installed by an
authorised electrician.
4
With external wireless IR sensor
With external wireless IR sensor
ETF-965-O
© 2013 OJ Electronics A/S
If the product has been damaged in any way, e.g. during transport,
it must be inspected and checked by authorised personnel before
being connected to the power supply.
The product carries a manufacturer's warranty if installed in
accordance with these instructions and applicable regulations.
Technical data
Supply voltage . . . . . . . . . . . . . . . . . . . 230 V AC ±15%, 50 Hz/60 Hz
Max. fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 A
Built-in circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-pole, 16 A
Output relay . . . . . . . . . . . . . . . . . . . . . . . . Make contact – SPST – NO
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Max. 16 A / 3600 W
Control principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM-control
Cycle time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-60 min
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0/+40°C
Setback temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ∆2-8°C
- control voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V AC
Frost protection temperature . . . . . . . . . . . . . . . . . . 5°C absolute fixed
- control voltage via rectifier diode . . . . . . . . . . . . . . . . . . . . . 230 V AC
Setting limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Min./max.
Sensor fault protection (E1). . . . . . . . Short-circuited or disconnected
Operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0/+40°C
IR sensor frequency band . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433 MHz
IR sensor transmission range . . . . . . . . . . . . . . . . . . . . . . . Max. 15 m
Battery type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CR123A
Expected battery lifetime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 years
Dimensions – thermostat . . . . . . . . . . . . . . . . . . H/81, W/81, D/38 mm
Dimensions – IR sensor . . . . . . . . . . . . . . . . . . . H/81, W/81, D/20 mm
Enclosure rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 21
The thermostat and sensor are maintenance free.