Type OTD2 with wireless IR floor sensor
Restoring factory settings
To restore factory settings, press and hold the programming button for 10 seconds. APP // AF will be shown on the display, indicating that all
factory settings have been restored.
Parameter
Max. temperature
Min. temperature
Max. limit temperature FLOOR
Min. limit temperature FLOOR
Average floor temperature
Average room temperature
Application
Offset
Night setback/ECO
IR sensor 1 readout/setup
IR sensor 2 readout/setup
If Controller (
) is selected under Application, the floor and room sensors are disconnected and heating is controlled on a scale of 0-10,
corresponding to 0-100% activated.
Setting up IR sensor 2
A second wireless IR sensor (
) can subsequently be added to the thermostat.
Press and hold the programming button for 3 seconds.
programming button several times until
thermostat in learning mode.
Press the connect button located under the cover of IR sensor 2. See figure 4.
Shown on display
: Room sensor only
: IR floor sensor only
: Room with IR floor sensor
: Controller
(only if installed)
will be shown on the display. Press the
flashes on the display. Press the up or down button to set the
© 2013 OJ Electronics A/S
Factory setting
40°C (0-40°C)
0°C (0-40°C)
28°C (15-55°C)
15°C (5-30°C)
X
0 (+/- 3°C)
5°C (2-8°C)
Fig