Herunterladen Inhalt Inhalt Diese Seite drucken

Fresh INTELLIVENT 2.0 Installationsanleitung Seite 6

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
3 Wiring
• Installation work should be performed by a qualified
electrician.
• The fan is double insulated and must not be earthed.
• The fan is fitted with a multi-pole switch and does not
require a pre-wired external switch.
1 Push the multi-pole switch up to position 0 – OFF.
2 The cable can be installed either along the surface using
entries A in the chassis or concealed using the B inlets
in the chassis. Both options are shown below. Use the
insulating sleeve supplied for the cable (FK).
3 If you use any of the B inlets, remove the concealed
round plastic cover by tapping inside the break-off
notch from the inside out to the back with a screwdriver,
for example.
Cable entries
A=surface
B=concealed
OFF
ON
6
A
B
B
A
A
B
A
B