6.2 The keys and their operations
6.2.1
button
Press
to start the heat pump unit, the LED display shows the desired water temperature for 5 seconds, then
shows the inlet water temperature and the operation mode.
Press
to stop the heat pump unit and show "OFF"
Notice : During the parameter checking and setting, press the
Press
again to turn on/off the machine.
6.2.2
button
Press
for 5s to change the " Heat MODE" or " Cool MODE" .
6.2.3
and
Water temperature setting :
Press
and
Parameter checking :
Press
first, then press
Parameter
d1
d2
d3
d4
d5
d6
d7
d8
d9
TIME checking :
Press
first, then press
press
once again to check " Automatic stop time " .
button
to set the water temperature directly.
to check the " User parameter from d1 to d9.
Name
Inlet water temperature
Outlet water temperature
Ambient temperature
Gas return temperature
Coil temperature
Gas exhaust temperature
Steps of electronic expansion valve
Compressor operating frequency
Powerful: 65,70,75Hz
Smart: 50,55,60Hz
Silent: 30,35,40,45Hz
Compressor current
to check "current time", press
to quick‐exit and save the current setting .
Range
‐9‐99 ℃
‐9‐99 ℃
(‐30℃)‐70℃
(‐30℃)‐70℃
(‐30℃)‐70℃
0‐C5℃(125℃)
0‐99
0‐99Hz
0‐30A
again to check the "Automatic start time",
- 17 -
Remarks
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
Real testing value
N*5
Real testing value value
Real testing value