Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Logic - Genius JA277K Gebrauchsanleitung - Anweisungen Zur Installation

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

The control unit is designed to house the anti-crushing sensor (optional) in the special connector M6.
To continue with the installation, cut off the electric power supply and follow the instructions for the anti-crushing sensor.

OPERATING LOGIC

Automatic
Semi-automatic
Automatic with stop
Step-step with stop
ANTI-CRUSHING SENSOR ( OPTIONAL )
Deactivated
Activated
CLOSING PHOTOCELL OPERATION
Stops and reverses the motion
Stops and,when released, reverses the motion
Note: all adjustments are performed with the control unit switched off and the gate closed.
GATE
STATUS
CLOSED
OPEN IN
PAUSE
CLOSING
OPENING
STOPPING
CLOSED
OPEN IN
PAUSE
CLOSING
OPENING
STOPPING
CLOSED
OPEN IN
PAUSE
CLOSING
OPENING
STOPPING
CLOSED
OPEN
CLOSING
OPENING
STOPPING
11. ANTI-CRUSHING SENSOR INSERTION
12. DIP-SWITCH SETTINGS (SW1)
13. OPERATING LOGIC
PULSE A
(total opening)
(partial opening)
Opens, pauses and closes
Reset the pause
Re-opens immediately
No effect. If in partial
opening mode, opens
completely
Closes immediately
Opens, pauses and closes
Re-closes immediately
Re-opens immediately
Re-closes immediately
Closes immediately
Opens, pauses and closes
Reset the pause
Re-opens immediately
Blocks operation
Closes immediately
Opens
Re-closes immediately
Re-opens immediately
Blocks operation
Closes immediately
PULSES
PULSE B
STOP
Blocks Pulse
Blocks
operation
No effect
Blocks Pulse
Blocks
operation
Blocks Pulse
Blocks
operation
Blocks Pulse
Blocks
operation
7
1
2
3
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
PHOTOCELLS
No effect
Blocks Pulse and suspends /
reset the pause
Blocks and reverses or stops
and starts after reset as per
dip-sw 4
No effect
No effect / Blocks Pulse
No effect
Anticipates closing 2
seconds after the release
Blocks and reverses or stops
and starts after reset as per
dip-sw 4
No effect
No effect / Blocks Pulse
No effect
Blocks Pulse and suspends /
reset the pause
Blocks and reverses or stops
and starts after reset as per
dip-sw 4
No effect
No effect / Blocks Pulse
No effect
Blocks Pulse
Blocks and reverses or stops
and starts after reset as per
dip-sw 4
No effect
No effect / Blocks Pulse
ENGLISH
4
OFF
ON

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis