MICROPROCESSOR CONTROL UNIT FOR SLIDING GATES
USER INSTRUCTIONS - INSTALLATION STANDARDS
Thanks to the high-power performance of its built-in microprocessor, this control unit for sliding gates offers a wide number
of services and adjustments. In addition, electronic power control guarantees a high safety level.
A sophisticated electronic control constantly monitors the power circuit and cuts off the unit when problems arise which
reduce the operating efficiency of the electronic clutch.
The main settings and operating modes can be defined using dip-switches while time and motor power adjustments are
performed using the trimmers installed on the electronic circuit board.
7 built-in LEDS constantly display the status of inputs, outputs in addition to any circuit malfunctions.
Power supply
Absorbed power
Max. motor load
Max. load on accessoies
Ambient temperature
Protection fuses
Operating logic
Opening /closing time
Pause time
Thrust force
Terminal board inputs
Radio control connector
Sensor connector
Terminal board outputs
Functions selected with dip-switches
Housing dimensions (external)
Housing degree of protection (external)
3. TERMINAL BOARD M1 (HIGH VOLTAGE) CONNECTIONS - DESCRIPTION
3.1 MAINS POWER
Terminals "1 - 2 - 3" (Live - Ground - Neutral), Power supply voltage 230 V~ 50/60 Hz.
WARNING: the ground connection is mandatory to ensure proper unit operation.
4. TERMINAL BOARD M2 (HIGH VOLTAGE) CONNECTIONS - DESCRIPTION
4.1 FLASHER
Terminals "4 - 5" (Live - Neutral). Use a flasher with an operating voltage of 230 V~ (40W max.). When power is supplied to the
system the flasher will blink once to confirm that the unit is properly connected to the electric power supply.
4.2 GEAR UNIT
Terminals "6 - 7 - 8" (Close - Common - Open). Connect the motor and relative condenser.
WARNING: if the gear unit is incorrectly connected or the connection is not completed, the unit will be inhibited and this
status will be indicated by diagnostic LED 7.
Notes:
1)
To install electric cables, us adequate rigid and/or flexible tubes.
2)
Always separate the low-voltage connection cables from the 230V~ power supply cables. Cables for the power
supply to the equipment must have a 1.5 mm
3)
The box features 4 break-through holes Ø25 where Pg16 cable clamps with minimum protection degree IP54
must be mounted (not supplied).
5. TERMINAL BOARD M3 (LOW VOLTAGE) CONNECTIONS - DESCRIPTION
5.1 GATE STATUS LED
Terminals "9-10". The signal led constantly displays gate status and motion. OFF = gate closed; ON = gate open;
SLOW FLASHING = gate opening; FAST FLASHING = gate closing.
1. GENERAL FEATURES
2. TECHNICAL FEATURES
Automatic with stop / Step-step with stop
Adjustable using trimmer (from 10 to 120 sec.)
Adjustable using trimmer (from 0 to 120 sec.)
Closing photocells / Opening-closing limit switch /
STOP / Mains power supply + Ground / Antenna
Radio receiver boards molex connector
Accessory power supply 24 V~ / Flasher /
section. To avoid interference, us separate sheathes.
2
5
230 V~ (+6 -10%) - 50/60 Hz.
550 W
500 W
500 mA
-20°C +50°C
3
Automatic / Semi-automatic /
Adjustable using trimmer
Total opening / Partial opening /
Anti-crushing sensor
Gate status led / Motor
Operating modes
Closing photocell reaction
90 x 195 x 250 mm.
IP54
ENGLISH