Quick installation and programming guide
This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The installation manual can be downloaded by going
WARNING
to the "Downloads" section of Erreka website:
http://www.erreka-automation.com
*
2
4 x 1mm
(max. 20m)
4 x 0,5mm
(max. 30m)
TA
VERY IMPORTANT:
The TC closing limit switch must be
installed in all cases, and TA opening limit
switches whenever the articulated arm is
installed.
Electrical wiring
A: Main power supply
B: LUMI flashing light
C: Photocells (Rx/Tx)
D: Pushbutton/key switch
E: Operator *:
2
motor: 4x1mm
2
brake: 2x1mm
encoder: shielded cable 2x0.5mm
F: LUMI built-in antenna
G: Electrolock
Elements of the complete installation
2
G
2
2 x 0,75mm
(max. 20m)
2
In dual leaf facilities without brake or
encoder, the following should be taken into
account when programming the operations:
when programming the closing of leaf 2 and the
leaf reaches the closing limit switch, wait for a
time equal to the lapse between leaves before
pressing ST1 to end programming. This ensures
that, during the closing operation, leaf 2 remains
at the closing limit switch during lapse until leaf
1 closes completely.
TC
TA
2 x 0,5mm
(max. 30m)
The electrolock is obligatory for operators without
lock (CL210 and CL250). For operators with lock, the
electrolock must be used for gate leaf lengths of over
1.8m.
*NOTE: the electrical installation of the operator can be
done correctly and straightforwardly using the cable with
AYCY8 code, which ERREKA can supply by metre. This
cable has the characteristics 4x1mm
2
((2x0.5mm
)) and was developed specifically for this use.
English
2 x 0,5mm
2
(max. 20m)
RG-58/U
2 x 0,5mm
(max. 20m)
2
2
3 x 1,5mm
(max. 30m)
E246A
2
2
+2x1mm
2
+
5

Werbung