- Push the test button at the front of the unit for 2 seconds. When
operating correctly, 4 beeps will sound - and the red LED will flash.
Product malfunctions
If the unit detects an error, the yellow light will flash and the unit
will beep twice every 10 seconds.
CO DETECTOR MAINTENANCE AND CARE
- This detector will alert you to dangerous CO concentrations in
your home when maintained properly. To maintain a good oper-
ating conditions we recommend:
- Test your detector at least once a month.
- Routinely clean the detector to prevent dust deposit. A vacuum
cleaner may be used for this purpose. Particularly clean the front
cover and the sides.
- Do not use cleaners, only use a damp cloth.
- Do not paint the detector.
ATTENTION:
The CO detector should be removed and stored in a safe place
to protect it from damage when cleaning or stripping wood floors,
12 GB/IE/NI