Herunterladen Inhalt Inhalt Diese Seite drucken

Lamborghini Caloreclima 55 PM/2-E Bedienungsanleitung Seite 13

Vorschau ausblenden Andere Handbücher für 55 PM/2-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
Should you notice the smell of gas, do not turn on/off any electrical switches. Open windows and
doors. Turn off the gas, and call a qualified technician.
The room where the burner is located must have those openings to the outside required by those local
regulations in force.
Never cover up the burner room's air vents, the burner's fan's air-intake openings, or any existing air
ducts or air gratings, thus avoiding:
- the formation of poisonous/explosive mixtures of gases in the burner room;
- combustion with insufficient air, which would be dangerous, costly and cause pollution.
The burner must at all times be protected from rain, snow and freezing.
The room where the burner is housed should be kept clean at all times, and there should be no
volatile substances in the vicinity, substances which could be sucked into the fan and could block up
the internal ducts of the burner or of the combustion head. Dust can be extremely harmful,particularly
when it gets onto the fan blades as this reduces ventilation and leads to pollution during combustion.
Dust can also build up on the rear of the flame stability disk inside the combustion head, leading to a
poor air-fuel mixture.
The burner must be fed with the type of fuel for which it was designed, as indicated on the data plate
and in the technical characteristics given in the present manual.
The fuel feed line must be sealed, and must be of the rigid variety, with an interposed metal expansion
bend with either a flange joint or nipple.
Furthermore, the feed line must be furnished with those regulation and safety devices required by
current local regulations.
Be particularly careful to ensure that no foreign bodies get into the feed line during installation.
Ensure that the electrical power supply used conforms to those technical characteristics given on the
data plate and in this present manual.
In accordance with current regulations, the electrical system must be connected to an efficient earth
system. The earth cable must be a couple of cm longer than the phase and neutral wires.
Should there be any doubts as to the correctness of the earthing, then this must be checked by a
qualified technician.
Should the burner's mains cable be found to be faulty, it should only be replaced by a qualified
technician.
Never touch the burner with wet parts of the body or in bare feet.
Never stretch the mains cables, and keep them well away from hot parts or other heat sources.
Having taken out all the parts from the box, check the contents and make sure that nothing has been
damaged during transportation. Should you have any doubts, do not use the burner but get
immediately in touch with the supplier.
All packaging material (wooden crates, cardboard, plastic bags, foamed plastic, clips, etc...) is a
potential source of both pollution and danger should it be left lying around, and as such should be
collected up and disposed of in the correct fashion (in a suitable place).